ntcTsAnlyAlmPcrDiscontinuity
NEWTEC-TSANALYSER-MIB ·
.1.3.6.1.4.1.5835.5.2.1400.1.6.7
Object
scalar
NEWTEC-TC-MIBNtcAlarmState
This alarm indicates that the difference between two consecutive PCR values exceeds the range [0-100] ms, while the 'discontinuity indicator' bit is not set. This bit in the Adaptation Field should trigger a reset of the PCR evaluation functionality. This variable indicates the current status of the alarm.
Context
- MIB
- NEWTEC-TSANALYSER-MIB
- OID
.1.3.6.1.4.1.5835.5.2.1400.1.6.7- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- ntcTsAnlyAlarm
- Siblings
- 7
Syntax
NEWTEC-TC-MIBNtcAlarmState
- Source
- NEWTEC-TC-MIBNtcAlarmState
- Base type
Enumeration
Values & Constraints
Type Values
0 | off |
1 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ntcTsAnlyAlmSyncLoss Alarm indicating that the synchronization with the Transport-Stream (TS) has
been lost. This conditions occurs when 2 or more consecutive corrupted SYNC
bytes are received. This v… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.1 |
| ntcTsAnlyAlmSyncByte This alarm is raised when a single corrupted SYNC byte is detected and cleared
when the next correct one appears. This variable indicates the current status
of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.2 |
| ntcTsAnlyAlmPat This alarm indicates that the 'Program Association Table' (PAT) can not be
detected properly in the stream. The PAT table id (0x00) should be detected in
a PID 0x0000 at least eve… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.3 |
| ntcTsAnlyAlmContinuityCount This alarm is raised when packets arrive out of sequence, get dropped or occur
more than once. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.4 |
| ntcTsAnlyAlmTransport This alarm condition is detected when the 'Transport Error indicator'-bit in
the TS-Header is set to '1' for a specific PID. The alarm condition is cleared
when no Transport Error… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.5 |
| ntcTsAnlyAlmPcrRepetition This alarm is raised if the spacing between two consecutive PCR values is more
than 40ms. The condition can occur when PCR packets get lost or when PCR
packets are not present at … | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.6 |
| ntcTsAnlyAlmPcrAccuracy This alarm condition occurs when the PCR accuracy exceeds +/- 500nsec. The
definition of the alarm is taken from TR101290. This variable indicates the
current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1400.1.6.8 |