ntcMultiDemodCfgRollOff

NEWTEC-MULTI-DEMOD-MIB · .1.3.6.1.4.1.5835.5.2.3300.1.3.1.6

Object

column r/w Enumeration
The receive filter Roll-off factor setting determines the spectrum excess
bandwidth by controlling the RCRO (Root Cosine Roll-off) factor of the matched
filter at the demodulator input. The lower the Roll-off factor the higher the
throughput. Note that increasing the throughput (higher symbolrate) requires
more power from the satellite or it will result in a lower carrier-to-noise.

Context

MIB
NEWTEC-MULTI-DEMOD-MIB
OID
.1.3.6.1.4.1.5835.5.2.3300.1.3.1.6
Type
column
Access
readwrite
Status
current
Parent
ntcMultiDemodCfgEntry
Table
ntcMultiDemodCfgTable
Siblings
18

Syntax

Enumeration

Values & Constraints

Enumerated Values
0auto
1rolloff5
2rolloff10
3rolloff15
4rolloff20
5rolloff25
6rolloff35

Related Objects

Sibling Objects