ntcDvbModAlmRefSynthOutOfLock
NEWTEC-DVBMODULATOR-MIB ·
.1.3.6.1.4.1.5835.5.2.1000.1.19.9
Object
scalar
NEWTEC-TC-MIBNtcAlarmState
This alarm is raised when the reference synthesizer is out of lock. It indicates a malfunction of the reference synthesizer hardware which generates the IFL carrier frequency. The presence of this alarm suppresses the IFL transmit of the the modulator. This variable indicates the current status of the alarm.
Context
- MIB
- NEWTEC-DVBMODULATOR-MIB
- OID
.1.3.6.1.4.1.5835.5.2.1000.1.19.9- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- ntcDvbModAlarm
- Siblings
- 18
Syntax
NEWTEC-TC-MIBNtcAlarmState
- Source
- NEWTEC-TC-MIBNtcAlarmState
- Base type
Enumeration
Values & Constraints
Type Values
0 | off |
1 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ntcDvbModAlmGeneralModulator This alarm is raised when there is a general modulator alarm. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.1 |
| ntcDvbModAlmLo1SynthOutOfLock This alarm is raised when the synthesizer of the first Local Oscillator is out
of lock. It indicates a malfunction of the synthesizer hardware which
generates the IFL carrier freq… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.10 |
| ntcDvbModAlmLo2SynthOutOfLock This alarm is raised when the synthesizer of the second Local Oscillator is
out of lock. It indicates a malfunction of the synthesizer hardware which
generates the IFL carrier fre… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.11 |
| ntcDvbModAlmNoCalibrationData This alarm is raised when there is no Calibration data available for the
modulator. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.12 |
| ntcDvbModAlmDacFailure This alarm is raised when there is a general DAC Failure. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.13 |
| ntcDvbModAlmBucPowerMinCurrent This alarm is raised when measured current for block up converter power is
below specified minimal value. This variable indicates the current status of
the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.14 |
| ntcDvbModAlmBucPowerOverload This alarm is raised when overload is detected. This variable indicates the
current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.15 |
| ntcDvbModAlmBucPowerSupply This alarm is raised when 24V/48V supply is not operational This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.16 |
| ntcDvbModAlmBucPowerCap This alarm is raised when there is too much output capacitance connected. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.17 |
| ntcDvbModAlmBucPowerShortCircuit This alarm is raised when short circuit is detected. This variable indicates
the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.18 |
| ntcDvbModAlmBucPowerHardware This alarm is raised when communication with block up converter power unit is
lost. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.19 |
| ntcDvbModAlmNoInputSignal This alarm is raised when no input signal is detected at the input of the
modulator. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.2 |
| ntcDvbModAlmBufferUnderflow This alarm is raised when the input data buffer to the modulator is empty.
This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.3 |
| ntcDvbModAlmBufferOverflow This alarm is raised when the input data buffer of the modulator is full. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.4 |
| ntcDvbModAlmNoInputFrameSync This alarm indicates loss of input framing on the incoming data of the
modulator. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.5 |
| ntcDvbModAlmNoBaseBandFrameSync This alarm indicates synchronization loss of the baseband framer on the
incoming data. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.6 |
| ntcDvbModAlmNoPhyLayerFrameSync This alarm indicates loss of synchronization between the physical layer
framing and the baseband frames. This variable indicates the current status of
the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.7 |
| ntcDvbModAlmSynthFail This alarm is raised when there is a failure with a synthesizer. It indicates
a malfunction of the synthesizer hardware which generates the IFL carrier
frequency. The presence of … | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.8 |