ntcDvbModAlmNoInputFrameSync
NEWTEC-DVBMODULATOR-MIB ·
.1.3.6.1.4.1.5835.5.2.1000.1.19.5
Object
scalar
NEWTEC-TC-MIBNtcAlarmState
This alarm indicates loss of input framing on the incoming data of the modulator. This variable indicates the current status of the alarm.
Context
- MIB
- NEWTEC-DVBMODULATOR-MIB
- OID
.1.3.6.1.4.1.5835.5.2.1000.1.19.5- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- ntcDvbModAlarm
- Siblings
- 18
Syntax
NEWTEC-TC-MIBNtcAlarmState
- Source
- NEWTEC-TC-MIBNtcAlarmState
- Base type
Enumeration
Values & Constraints
Type Values
0 | off |
1 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ntcDvbModAlmGeneralModulator This alarm is raised when there is a general modulator alarm. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.1 |
| ntcDvbModAlmLo1SynthOutOfLock This alarm is raised when the synthesizer of the first Local Oscillator is out
of lock. It indicates a malfunction of the synthesizer hardware which
generates the IFL carrier freq… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.10 |
| ntcDvbModAlmLo2SynthOutOfLock This alarm is raised when the synthesizer of the second Local Oscillator is
out of lock. It indicates a malfunction of the synthesizer hardware which
generates the IFL carrier fre… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.11 |
| ntcDvbModAlmNoCalibrationData This alarm is raised when there is no Calibration data available for the
modulator. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.12 |
| ntcDvbModAlmDacFailure This alarm is raised when there is a general DAC Failure. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.13 |
| ntcDvbModAlmBucPowerMinCurrent This alarm is raised when measured current for block up converter power is
below specified minimal value. This variable indicates the current status of
the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.14 |
| ntcDvbModAlmBucPowerOverload This alarm is raised when overload is detected. This variable indicates the
current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.15 |
| ntcDvbModAlmBucPowerSupply This alarm is raised when 24V/48V supply is not operational This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.16 |
| ntcDvbModAlmBucPowerCap This alarm is raised when there is too much output capacitance connected. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.17 |
| ntcDvbModAlmBucPowerShortCircuit This alarm is raised when short circuit is detected. This variable indicates
the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.18 |
| ntcDvbModAlmBucPowerHardware This alarm is raised when communication with block up converter power unit is
lost. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.19 |
| ntcDvbModAlmNoInputSignal This alarm is raised when no input signal is detected at the input of the
modulator. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.2 |
| ntcDvbModAlmBufferUnderflow This alarm is raised when the input data buffer to the modulator is empty.
This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.3 |
| ntcDvbModAlmBufferOverflow This alarm is raised when the input data buffer of the modulator is full. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.4 |
| ntcDvbModAlmNoBaseBandFrameSync This alarm indicates synchronization loss of the baseband framer on the
incoming data. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.6 |
| ntcDvbModAlmNoPhyLayerFrameSync This alarm indicates loss of synchronization between the physical layer
framing and the baseband frames. This variable indicates the current status of
the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.7 |
| ntcDvbModAlmSynthFail This alarm is raised when there is a failure with a synthesizer. It indicates
a malfunction of the synthesizer hardware which generates the IFL carrier
frequency. The presence of … | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.8 |
| ntcDvbModAlmRefSynthOutOfLock This alarm is raised when the reference synthesizer is out of lock. It
indicates a malfunction of the reference synthesizer hardware which generates
the IFL carrier frequency. The… | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.1000.1.19.9 |