ntcAsiInAlmNoInputDataAsi2
NEWTEC-ASIIN-MIB ·
.1.3.6.1.4.1.5835.5.2.800.1.9.9
Object
scalar
NEWTEC-TC-MIBNtcAlarmState
This alarm is raised when no input data is detected at the ASI2 input. This variable indicates the current status of the alarm.
Context
- MIB
- NEWTEC-ASIIN-MIB
- OID
.1.3.6.1.4.1.5835.5.2.800.1.9.9- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- ntcAsiInAlarm
- Siblings
- 8
Syntax
NEWTEC-TC-MIBNtcAlarmState
- Source
- NEWTEC-TC-MIBNtcAlarmState
- Base type
Enumeration
Values & Constraints
Type Values
0 | off |
1 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ntcAsiInAlmGeneralAsiInput This alarm is raised when there is a general ASI input alarm. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.1 |
| ntcAsiInAlmNoInputSignal This alarm is raised when no input signal is detected at the selected ASI
input. This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.2 |
| ntcAsiInAlmNoInputData This alarm is raised when no input data is detected at the selected ASI input.
This variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.3 |
| ntcAsiInAlmInvalidTsBitRate This alarm is raised when the measured input Transport-Stream (TS) bitrate is
higher or lower than the expected value. This variable indicates the current
status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.4 |
| ntcAsiInAlmBufferOverflow This alarm is raised when the input data buffer is full. This variable
indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.5 |
| ntcAsiInAlmNoInputSignalAsi1 This alarm is raised when no input signal is detected at the ASI1 input. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.6 |
| ntcAsiInAlmNoInputSignalAsi2 This alarm is raised when no input signal is detected at the ASI2 input. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.7 |
| ntcAsiInAlmNoInputDataAsi1 This alarm is raised when no input data is detected at the ASI1 input. This
variable indicates the current status of the alarm. | scalar | NEWTEC-TC-MIBNtcAlarmState | .1.3.6.1.4.1.5835.5.2.800.1.9.8 |