psInput
NETSURE-NCU-MIB ·
.1.3.6.1.4.1.6302.2.1.2.6
Object
node
No description available.
Context
- MIB
- NETSURE-NCU-MIB
- OID
.1.3.6.1.4.1.6302.2.1.2.6- Type
- node
- Parent
- system
- Siblings
- 18
- Children
- 6
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| systemStatus Status of the complete plant (highest alarm). One of
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'ab… | scalar | Status | .1.3.6.1.4.1.6302.2.1.2.1 |
| psSMNumber | node | - | .1.3.6.1.4.1.6302.2.1.2.10 |
| psRectifier | node | - | .1.3.6.1.4.1.6302.2.1.2.11 |
| psDistribution | node | - | .1.3.6.1.4.1.6302.2.1.2.12 |
| psConverter | node | - | .1.3.6.1.4.1.6302.2.1.2.13 |
| psControl | node | - | .1.3.6.1.4.1.6302.2.1.2.14 |
| psEquipmentSignalTable Table of indexed equipment signal values. | table | - | .1.3.6.1.4.1.6302.2.1.2.15 |
| psSetting | node | - | .1.3.6.1.4.1.6302.2.1.2.16 |
| psFCUPlus | node | - | .1.3.6.1.4.1.6302.2.1.2.19 |
| systemVoltage System voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.2 |
| psInverter | node | - | .1.3.6.1.4.1.6302.2.1.2.21 |
| psSolar | node | - | .1.3.6.1.4.1.6302.2.1.2.25 |
| systemCurrent System current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.3 |
| systemUsedCapacity Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.4 |
| psBattery | node | - | .1.3.6.1.4.1.6302.2.1.2.5 |
| psTemperature | node | - | .1.3.6.1.4.1.6302.2.1.2.7 |
| psStatusCommunication The status of communication with the Power System. interrupt(3) indicates
some errors occurred between Power System and agent. | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.8 |
| psStatusBatteryMode The status of battery modes,
FloatCharging(2),
ShortTest(3),
BoostChargingForTest(4),
ManualTesting(5),
PlanTesting(6),
ACFailTesting(7),
ACFail(8),
ManualBoostCharging(9),
AutoB… | scalar | Enumeration | .1.3.6.1.4.1.6302.2.1.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| psInputLineAVoltage The AC line A voltage, stored as mV. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.1 |
| psInputLineBVoltage The AC line B voltage, stored as mV. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.2 |
| psInputLineCVoltage The AC line C voltage, stored as mV. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.3 |
| psInputPhaseACurrent The AC Phase A current, stored as mA. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.4 |
| psInputPhaseBCurrent The AC Phase B current, stored as mA. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.5 |
| psInputPhaseCCurrent The AC Phase C current, stored as mA. The integer 2147483647
represents invalid value. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.6 |