bsciDevAdminEntry
NETLINK-SPECIFIC-MIB ·
.1.3.6.1.4.1.173.7.3.4.5.1
Object
row
mandatory
A BSCI Interactive Device entry containing objects relating to the device that are configurable by the user.
Context
- MIB
- NETLINK-SPECIFIC-MIB
- OID
.1.3.6.1.4.1.173.7.3.4.5.1- Type
- row
- Status
- mandatory
- Parent
- bsciDevAdminTable
- Table
- bsciDevAdminTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bsciDevAdminControlUnitID mandatory Control Unit identifier. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.5.1.1 |
| bsciDevAdminDeviceUnitID mandatory Device Unit identifier. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.5.1.2 |
| bsciDevAdminConnectionID mandatory The BSCI port connection ID for the device. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.5.1.3 |
| bsciDevAdminSingleUserVC mandatory Specifies whether each end of the connection is within
a same Control Unit/Device Type pair. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.5.1.4 |
| bsciDevAdminTransTextSupported mandatory Causes all characters transmitted to be treated as data. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.5.1.5 |
| bsciDevAdminPrinterAttached mandatory Specifies whether the device has a printer attached. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.5.1.6 |
| bsciDevAdminRowStatus mandatory This variable is used to manage the creation and deletion
of conceptual rows in the bsciDevAdminTable and follows the
SNMPv2 RowStatus conventions by supporting the following valu… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.173.7.3.4.5.1.7 |
| bsciDevAdminDisableStatusRequest mandatory Determines how the BSCI port will report the status
of the attached device. Normal status- the port will
report what the device reports. No status- the port will
report status o… | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.5.1.8 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| nlIfRlp mandatory The RLP number on the node. RLP numbers 1-8 are Physical
RLP cards, and RLP number 250, 251 and 252 define IP, IPX and LLC2
interfaces respectively. | column | Integer32 | .1.3.6.1.4.1.173.7.4.1.1.1 |
| nlIfPort mandatory The Port number on the RLP. Port numbers 1-8 are
known to be physical ports, and 9-64 are logical ports. If the
RLP number identifies an IP, IPX or LLC2 interface, then the port … | column | Integer32 | .1.3.6.1.4.1.173.7.4.1.1.2 |
| bsciDevAdminControlUnitID mandatory Control Unit identifier. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.5.1.1 |
| bsciDevAdminDeviceUnitID mandatory Device Unit identifier. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.5.1.2 |