voiceIfCodecG723MaxPTime

MX-VOICEIF-MIB · .1.3.6.1.4.1.4935.15.30.1.20.1.19

Object

column r/w Unsigned32
Longest packetization period allowed for the G.723 codec.
              
Expressed in milliseconds.  Authorized values go up to 120,
in discrete steps of 30 ms, and start at the one specified
by variable voiceIfCodecG723MinPTime.
              
This variable's semantics are different depending on
protocol and/or hardware platforms.
Please refer to the documentation for more details.

Context

MIB
MX-VOICEIF-MIB
OID
.1.3.6.1.4.1.4935.15.30.1.20.1.19
Type
column
Access
readwrite
Status
current
Parent
voiceIfCodecEntry
Table
voiceIfCodecTable
Siblings
28

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 30-30 range: 60-60 range: 90-90 range: 120-120

Related Objects

Sibling Objects