r2DigitTimerVariantsMfcPulseInterDigitTimeout
MX-R2-MIB ·
.0.1875.1.100.400.1.400
Object
column
r/w
Integer32
MFC Pulse Inter Digit Timeout
The minimum delay between the end of transmission of the last
signal of the compelled cycle and the start of the next one.
This value is expressed in milliseconds (ms).
Context
- MIB
- MX-R2-MIB
- OID
.0.1875.1.100.400.1.400- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- r2DigitTimerVariantsEntry
- Table
- r2DigitTimerVariantsTable
- Siblings
- 8
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-1000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| r2DigitTimerVariantsInterfaceName Interface Name
Identifies the interface. | column | OctetString | .0.1875.1.100.400.1.100 |
| r2DigitTimerVariantsOverrideDefault Override Default
Overrides the default setting of R2 Digit timers for the
CountrySelection and InterfaceName.
* Disable: The interface uses the def… | column | MX-TCMxEnableState | .0.1875.1.100.400.1.300 |
| r2DigitTimerVariantsMfCongestionToneDuration MF Congestion Tone Duration
Allows the administrator to specifically configures the
duration of the transmission of the congestion tone. The
special value '0' sets … | column | Integer32 | .0.1875.1.100.400.1.350 |
| r2DigitTimerVariantsMfcPulseMinOnTimeout MFC Minimum Pulse OnTimeout
The minimum time a backward tone can be on from the backward
perspective.
This value is expressed in milliseconds (ms). | column | Integer32 | .0.1875.1.100.400.1.500 |
| r2DigitTimerVariantsMfcMaxSequenceTimeout MFC Maximum Sequence Timeout
The maximum time for a complete compelled signaling cycle
from the forward perspective.
This value is expressed in milli… | column | Integer32 | .0.1875.1.100.400.1.600 |
| r2DigitTimerVariantsMfcMaxOnTimeout MFC Maximum On Timeout
The maximum time a forward tone can be on from the forward
perspective.
This value is expressed in milliseconds (ms). | column | Integer32 | .0.1875.1.100.400.1.700 |
| r2DigitTimerVariantsMfcMaxOffTimeout MFC Maximum Off Timeout
The maximum time a forward tone can be off from the forward
perspective.
This value is expressed in milliseconds (ms). | column | Integer32 | .0.1875.1.100.400.1.800 |
| r2DigitTimerVariantsResetSpecific Reset Specific
Resets specific settings of R2 Digit Timers parameters with
the default country settings. This command is used to
retrieve the default country config… | column | Enumeration | .0.1875.1.100.400.1.900 |