realCOMMaxConnection
MOXA-W2x50A-MIB ·
.1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.2
Object
column
r/w
Integer32
Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specific host can access this port of the NPort W2x50A series device server, and the Real COM driver on that host will have full control over the port. Max. connection = 1: Allows only a single host's Real COM driver to open the specific NPort W2x50A series device server's serial port. Max connection = 2 to 8: Allows 2 to 8 hosts' Real COM drivers to open the specific NPort W2x50A series device server's serial port, at the same time. When multiple hosts' Real COM drivers open the serial port at the same time, the COM driver only provides a pure data tunnel without control ability. The serial port parameter will use the firmware settings instead of getting the settings from your application program (AP).
Context
- MIB
- MOXA-W2x50A-MIB
- OID
.1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- realCOMEntry
- Table
- realCOMTable
- Siblings
- 5
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| realCOMTcpAliveCheck The TCP alive check time.
0 min: TCP connection will not be closed when the
TCP connection is idle.
1 to 99 min: The NPort W2x50A series device server
automatically closes the TCP… | column | Integer32 | .1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.1 |
| realCOMIgnoreJammedIp Previously, when Max connection was set to a value
greater than 1, and the serial device was
transmitting data, if any one of the connected hosts
stopped responding, the serial de… | column | Enumeration | .1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.3 |
| realCOMAllowDriverControl If Max connection is greater than 1, NPort will
ignore driver control commands from all connected
hosts. However, if you set Allow driver control to
YES, control commands will be … | column | Enumeration | .1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.4 |
| realCOMConnectionDownRTS For some applications, serial devices must obtain
the Ethernet link status by reading the RTS signal from the
NPort W2x50A series device server. If this setting is
set to 'always … | column | Enumeration | .1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.5 |
| realCOMConnectionDownDTR For some applications, serial devices must obtain
the Ethernet link status by reading the DTR signal from the
NPort W2x50A series device server. If this setting is
set to 'always … | column | Enumeration | .1.3.6.1.4.1.8691.2.13.1.4.1.2.1.1.1.6 |