realCOMMaxConnection

MOXA-IAW5x50A_IO-MIB · .1.3.6.1.4.1.8691.2.21.1.4.1.2.1.1.1.2

Object

column r/w Integer32
Max connection is usually used when the user needs
to receive data from different hosts simultaneously.
The factory default is 1. In this case, only one
specific host can access this port of the NPort
		IAW5x50A_IO series device server, and the Real COM driver
		on that host will have full control over the port.
Max. connection = 1:
Allows only a single host's Real COM driver to open
the specific NPort IAW5x50A_IO series device server's
serial port.
Max connection = 2 to 8:
Allows 2 to 8 hosts' Real COM drivers to open the
specific NPort IAW5x50A_IO series device server's
		serial port, at the same time. When multiple hosts'
		Real COM drivers open the serial port at the same
		time, the COM driver only provides a pure data tunnel
without control ability. The serial port parameter
will use the firmware settings instead of getting
the settings from your application program (AP).

Context

MIB
MOXA-IAW5x50A_IO-MIB
OID
.1.3.6.1.4.1.8691.2.21.1.4.1.2.1.1.1.2
Type
column
Access
readwrite
Status
current
Parent
realCOMEntry
Table
realCOMTable
Siblings
5

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects