upsConfigOutputPower
MITSUBISHI-UPS-MIB ·
.0.13891.101.9.6
Object
scalar
mandatory
NonNegativeInteger
The magnitude of the nominal true power rating (watts).
Context
- MIB
- MITSUBISHI-UPS-MIB
- OID
.0.13891.101.9.6- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsConfig
- Siblings
- 9
Syntax
NonNegativeInteger
- Source
- NonNegativeInteger
- Base type
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsConfigInputVoltage mandatory The magnitude of the nominal input voltage (RMS Volts).
On those systems which support read-write access to this
object, if there is an attempt to set this variable to
a value t… | scalar | NonNegativeInteger | .0.13891.101.9.1 |
| upsConfigHighVoltageTransferPoint mandatory The maximum line voltage (RMS Volts) allowed before the UPS
system transfers to battery backup. | scalar | NonNegativeInteger | .0.13891.101.9.10 |
| upsConfigInputFreq mandatory The nominal input frequency (0.1 Hertz). On those systems
which support read-write access to this object, if there is
an attempt to set this variable to a value that is not
suppo… | scalar | NonNegativeInteger | .0.13891.101.9.2 |
| upsConfigOutputVoltage mandatory The magnitude of the nominal output voltage (RMS Volts).
On those systems which support read-write access to this
object, if there is an attempt to set this variable to
a value … | scalar | NonNegativeInteger | .0.13891.101.9.3 |
| upsConfigOutputFreq mandatory The nominal output frequency (0.1 Hertz). On those systems
which support read-write access to this object, if there is
an attempt to set this variable to a value that is not
sup… | scalar | NonNegativeInteger | .0.13891.101.9.4 |
| upsConfigOutputVA mandatory The magnitude of the nominal Volt-Amp rating (Volt-Amps). | scalar | NonNegativeInteger | .0.13891.101.9.5 |
| upsConfigLowBattTime mandatory The value of upsEstimatedMinutesRemaining at which a
lowBattery condition is declared. For agents which
support only discrete (discontinuous) values, then the
agent shall round u… | scalar | NonNegativeInteger | .0.13891.101.9.7 |
| upsConfigAudibleStatus mandatory The requested state of the audible alarm. When in
the disabled state, the audible alarm should never
sound. The enabled state is self-describing. Setting
this object to muted(3… | scalar | Enumeration | .0.13891.101.9.8 |
| upsConfigLowVoltageTransferPoint mandatory The minimum input line voltage (RMS Volts) allowed before
the UPS system transfers to battery backup. | scalar | NonNegativeInteger | .0.13891.101.9.9 |