upsmgBatteryRechargeLevel
MG-SNMP-UPS-MIB ·
.1.3.6.1.4.1.705.1.5.4
Object
scalar
mandatory
Integer32
The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power returns. This value is computed from upsmgConfigRechargeTime (the delay), upsmgBatteryLevel (the actual level) and the UPS charge rate.
Context
- MIB
- MG-SNMP-UPS-MIB
- OID
.1.3.6.1.4.1.705.1.5.4- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsmgBattery
- Siblings
- 16
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsmgBatteryRemainingTime mandatory The time remaining actual charge vs actual load (dynamic). | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.1 |
| upsmgBatteryNoBattery mandatory The UPS has no Battery status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.10 |
| upsmgBatteryReplacement mandatory The UPS Battery to be replaced status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.11 |
| upsmgBatteryUnavailableBattery mandatory The UPS Battery is unavailable status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.12 |
| upsmgBatteryNotHighCharge mandatory The UPS Battery quit high condition status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.13 |
| upsmgBatteryLowBattery mandatory The battery low status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.14 |
| upsmgBatteryChargerFault mandatory The UPS Battery is not charging status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.15 |
| upsmgBatteryLowCondition mandatory The UPS is at low condition status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.16 |
| upsmgBatteryLowRecharge mandatory The UPS Battery is not recharged status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.17 |
| upsmgBatteryLevel mandatory The battery level as a percentage of charge. | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.2 |
| upsmgBatteryRechargeTime mandatory The actual operational battery recharge time to set point
equal to upsmgConfigRechargeLevel. This value is computed from
upsmgConfigRechargeLevel (level to reach), upsmgBatteryLev… | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.3 |
| upsmgBatteryVoltage mandatory The actual battery voltage. | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.5 |
| upsmgBatteryCurrent mandatory The actual battery current. | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.6 |
| upsmgBatteryTemperature mandatory The battery temperature. | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.7 |
| upsmgBatteryFullRechargeTime mandatory The battery full recharge time (from 0 to 100 percent)
at current load. | scalar | Integer32 | .1.3.6.1.4.1.705.1.5.8 |
| upsmgBatteryFaultBattery mandatory The battery fault status. | scalar | Enumeration | .1.3.6.1.4.1.705.1.5.9 |