mgreceptacleLevel

MG-SNMP-UPS-MIB · .1.3.6.1.4.1.705.1.3.2.1.2

Object

column mandatory r/w Integer32
The level of receptacle.
              
Setting this object to value invalid(2) has the effect of
invalidating the corresponding entry in the upsmgReceptaclesTable.
It is an implementation-specific matter as to wether the agent
removes an invalidated entry from the table. Accordingly,
management stations must be prepared to receive tabular
information from agents that corresponds to entry not currently
in use. Proper interpretation of such entries requires
examination of the relevant receptacleLevel object.
Values 1 and 4 are reserved, value 3 is used to identify a simple
one-level receptacle, and values greater than 4 represent a
group of equivalent receptacles.

Context

MIB
MG-SNMP-UPS-MIB
OID
.1.3.6.1.4.1.705.1.3.2.1.2
Type
column
Access
readwrite
Status
mandatory
Parent
upsmgReceptaclesEntry
Table
upsmgReceptaclesTable
Siblings
8

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects