mefSoamLmCfgFrameSize

MEF-SOAM-PM-MIB · .1.3.6.1.4.1.15007.1.3.1.2.1.1.8

Object

column r/w bytes Unsigned32
This object specifies the Loss Measurement frame size between
64 bytes and the maximum transmission unit of the EVC. 
              
The range of frame sizes from 64 through 2000 octets need to be
supported, and the range of frame sizes from 2001 through 9600 octets
is suggested be supported.  
              
The adjustment to the frame size of the standard frame size is 
accomplished by the addition of a Data or Test TLV. A Data or Test TLV
is only added to the frame if the frame size is greater than 64 bytes.
              
This object is only valid for the entity transmitting the Loss
Measurement frames, type 'lmSlm', and is ignored by the
entity receiving frames. It is not applicable for the 'lmCcm' or 
'lmLmm' types.
              
This object can only be written at row creation time and cannot be 
modified once it has been created.

Context

MIB
MEF-SOAM-PM-MIB
OID
.1.3.6.1.4.1.15007.1.3.1.2.1.1.8
Type
column
Access
readwrite
Status
current
Units
bytes
Parent
mefSoamLmCfgEntry
Table
mefSoamLmCfgTable
Siblings
33

Syntax

bytes Unsigned32

Values & Constraints

Object Constraints
range: 64-9600

Related Objects

Sibling Objects