ifBasicSignalFarEndLoopbackTimeout

LUM-IFBASIC-MIB · .1.3.6.1.4.1.8708.2.46.2.4.1.1.7

Object

column r/w LUM-TCTime7200min
Timeout for far end loopback (a.k.a. terminal
loopback for a client interface and facility
loopback for a line interfac) to make sure
connection to node is not lost if ppp link is
broken. The unit is minutes. The value 0 is used in
SNMP to indicate that the setting will last forever.
              
Note! This attribute is not saved in backup,
meaning the loopback will be set to disabled
when rebooting CU.

Context

MIB
LUM-IFBASIC-MIB
OID
.1.3.6.1.4.1.8708.2.46.2.4.1.1.7
Type
column
Access
readwrite
Status
current
Parent
ifBasicSignalEntry
Table
ifBasicSignalTable
Siblings
26

Syntax

LUM-TCTime7200min
Source
LUM-TCTime7200min
Base type
Integer32

Values & Constraints

Type Constraints
range: 0..7200 range: 2147483647