ifAmplifierModuleHighPumpCurrent
LUM-IFAMPLIFIER-MIB ·
.1.3.6.1.4.1.8708.2.65.2.3.1.1.7
Object
column
LUM-TCFaultStatusWithNA
The actual pump current of any pump in the module is over the module internal pump current alarm threshold.
Context
- MIB
- LUM-IFAMPLIFIER-MIB
- OID
.1.3.6.1.4.1.8708.2.65.2.3.1.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ifAmplifierModuleEntry
- Table
- ifAmplifierModuleTable
- Siblings
- 11
Values & Constraints
Type Values
1 | ok |
2 | alarm |
2147483647 | notApplicable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ifAmplifierModuleIndex An index assigned to each entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.65.2.3.1.1.1 |
| ifAmplifierModuleColdRestart Software initiated cold restart of the Amplifier Module.
Cold restart process may take a few seconds, during this period traffic will be disturbed. | column | Enumeration | .1.3.6.1.4.1.8708.2.65.2.3.1.1.10 |
| ifAmplifierModuleSubrack The subrack of the entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.65.2.3.1.1.11 |
| ifAmplifierModuleSlot The slot of the entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.65.2.3.1.1.12 |
| ifAmplifierModuleName The management name of the module object. | column | LUM-TCMgmtNameString | .1.3.6.1.4.1.8708.2.65.2.3.1.1.2 |
| ifAmplifierModuleUId A unique identifier assigned to each entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.65.2.3.1.1.3 |
| ifAmplifierModuleTemperature The actual module temperature in units of
0.1 degrees Celsius. | column | LUM-TCInteger32WithNA | .1.3.6.1.4.1.8708.2.65.2.3.1.1.4 |
| ifAmplifierModuleInfo Module information about firmware and serial number of the module on the board. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.8708.2.65.2.3.1.1.5 |
| ifAmplifierModuleHighModuleTemperature The actual temperature is over the module internal temperature alarm threshold. | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.65.2.3.1.1.6 |
| ifAmplifierModuleHighPumpTemperature The actual pump temperature of any pump in the module
is over the module internal pump temperature alarm threshold. | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.65.2.3.1.1.8 |
| ifAmplifierModuleCommunicationFailure Communication between the module and the traffic unit has
failed.
A: The module does not respond.
D: Communication works. | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.65.2.3.1.1.9 |