auxSnmpInconsistentConfiguration
LUM-AUX-MIB ·
.1.3.6.1.4.1.8708.2.29.2.2.1.1.15
Object
column
LUM-TCFaultStatus
Changes in the configuration of the remote
equipment has been detected.
This could happen if some other SNMP-manager
is manipulating the configuration, or the
configuration is changed via some local CLI.
A(ctivation): Changes in the configuration detected
D(e-activation): Configuration is consistent
Context
- MIB
- LUM-AUX-MIB
- OID
.1.3.6.1.4.1.8708.2.29.2.2.1.1.15- Type
- column
- Access
- readonly
- Status
- current
- Parent
- auxSnmpEntry
- Table
- auxSnmpTable
- Siblings
- 15
Values & Constraints
Type Values
1 | ok |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| auxSnmpIndex An arbitrary index assigned to each
equipment. | column | Unsigned32 | .1.3.6.1.4.1.8708.2.29.2.2.1.1.1 |
| auxSnmpOperStatus The operational state for the object.
notPresent - The HW related to the object
is not available
down - The object is de-activated or there are
fault… | column | LUM-TCBoardOrInterfaceOperStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.10 |
| auxSnmpInvPhysIndexOrZero The row in the invPhysTable for this interface.
Set to 0 if not known. | column | Unsigned32 | .1.3.6.1.4.1.8708.2.29.2.2.1.1.11 |
| auxSnmpHostUnreachable Can not contact the remote external equipment.
Check address and community strings.
A(ctivation): Contact lost
D(e-activation): Contact stablished ag… | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.12 |
| auxSnmpSnmpError Can not login to the remote external equipment
A(ctivation): Contact lost
D(e-activation): Contact stablished again | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.13 |
| auxSnmpUnexpectedEquipmentType The remote external equipment is not of the
expected type.
A(ctivation): Wrong equipment detected
D(e-activation): Expected equipment detected | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.14 |
| auxSnmpConfigurationProblem The SNMP-manager can not configure the remote
equipment.
A possible cause could be that the writeCommunity
does not match the remote equipment.
A(cti… | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.16 |
| auxSnmpName The name of the SNMP managed equipment. | column | LUM-TCMgmtNameString | .1.3.6.1.4.1.8708.2.29.2.2.1.1.2 |
| auxSnmpDescr User configurable label. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.8708.2.29.2.2.1.1.3 |
| auxSnmpAddress The IP address for the SNMP
managed equipment. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.8708.2.29.2.2.1.1.4 |
| auxSnmpVersion SNMP protocol version. | column | Enumeration | .1.3.6.1.4.1.8708.2.29.2.2.1.1.5 |
| auxSnmpPort The port number for the
SNMP managed equipment. | column | Unsigned32 | .1.3.6.1.4.1.8708.2.29.2.2.1.1.6 |
| auxSnmpReadCommunity The community string to use when
reading information from the SNMP
managed equipment. | column | OctetString | .1.3.6.1.4.1.8708.2.29.2.2.1.1.7 |
| auxSnmpWriteCommunity The community string to use when
configuring the SNMP managed equipment. | column | OctetString | .1.3.6.1.4.1.8708.2.29.2.2.1.1.8 |
| auxSnmpAdminStatus The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. … | column | LUM-TCBoardOrInterfaceAdminStatus | .1.3.6.1.4.1.8708.2.29.2.2.1.1.9 |