lgpPwrTransferToBypass
LIEBERT-GP-POWER-MIB ·
.1.3.6.1.4.1.476.1.42.3.5.6.6
Object
Transfer to Bypass Command. This command will initiate a transfer of the load to the bypass of the system. This command should be sent with a parameter of 1. This variable doesn't return a value when read.
Context
- MIB
- LIEBERT-GP-POWER-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.5.6.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- lgpPwrControl
- Siblings
- 9
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpPwrWellKnownControlPoints This sub-tree registers well known Liebert Power Control
Points. The object identifier names usually imply locations
where control of a device is available -- such 'output' or
'l… | node | - | .1.3.6.1.4.1.476.1.42.3.5.6.1 |
| lgpPwrOutputOffDelayWithoutRestart Output Off Delay without Restart Command. This command will turn off
the output of the device after a specified delay. The number of seconds
to delay is subject to the precision… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.10 |
| lgpPwrLoadCircuitTable A list of load circuits that can be controlled(opened or closed).
The NMS cannot create or delete rows from the table.
The rows are created by the agent based upon the capabilitie… | table | - | .1.3.6.1.4.1.476.1.42.3.5.6.2 |
| lgpPwrAlarmSilence Audible Alarm Silence Command. This command turns off the device's
audible alarm. It will not affect the status of the alarm(s) that
caused the audible alarm. This command shou… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.3 |
| lgpPwrBatteryTest Battery Test Command. This command will initiate a battery test if
one is not already in progress, or abort the current test if it is in
progress. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.6.4 |
| lgpPwrUpsAbortCommand UPS Abort command. This command will abort the pending command on the
device. There is no guarantee a client using the abort command will
cancel a command sent moments before fr… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.5 |
| lgpPwrTransferToInverter Transfer to Inverter Command. This command will initiate a transfer
of the load to the inverter of the system. This command should be sent
with a parameter of 1. This variable d… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.7 |
| lgpPwrOutputOnDelay Output On Delay Command. This command will turn on the output of the
device after a user specified delay. The number of seconds to delay
is subject to the precision of the devic… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.8 |
| lgpPwrOutputOffDelayWithRestart Output Off Delay with Restart Command. This command will turn off the
output of the device after a user specified delay. The number
of seconds to delay is subject to the precisi… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.6.9 |