lgpPwrTopMaximumFrameCapacity
LIEBERT-GP-POWER-MIB ·
.1.3.6.1.4.1.476.1.42.3.5.7.6
Object
The maximum device system capacity.
Context
- MIB
- LIEBERT-GP-POWER-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.5.7.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- Volt-Amp
- Parent
- lgpPwrTopology
- Siblings
- 14
Syntax
Volt-Amp SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpPwrUpsTopOffline The UPS has an offline topology. Under normal operating conditions,
AC power from the utility passes straight through the UPS
to the critical load. The inverter is used to conve… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.1 |
| lgpPwrStateModuleType UPS module type.
SMS -- Single Module System
1 + 1 -- Redundant system for capacity
1 + N -- Distributed multi-module system
N + 1 -- A multi-module system with one bypass fo… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.10 |
| lgpPwrStateBypassInputConfig Bypass input wire physical wiring configuration.
singlePhase2WireL1WithReturn
Single phase input with 2 wires (Line 1, and Return).
twoPhase2WireL1L2
Two phase input with … | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.11 |
| lgpPwrStateOutputConfig Output wire physical wiring configuration.
singlePhase2WireL1WithReturn
Single phase output with 2 wires (Line 1, and Return).
twoPhase2WireL1L2
Two phase output with 2 wi… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.12 |
| lgpPwrRectifierPassiveFilterInstalled Indicates whether the rectifier passive filter is installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.13 |
| lgpPwrRectifierTrapInstalled Indicates whether the rectifier input passive filter is installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.14 |
| lgpPwrRectifierActiveFilterInstalled Indicates whether the rectifier active filter is installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.15 |
| lgpPwrUpsTopLineInteractive The UPS has a line-interactive topology. This topology
resembles the offline product, but inserts a transformer or inductor
in series between the utility power source and the loa… | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.2 |
| lgpPwrUPSTopDualInput The system has separate input sources for the bypass and inverter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.3 |
| lgpPwrTopFrequencyConverter The system has a frequency converter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.4 |
| lgpPwrTopVoltageConverter The system has a voltage converter. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.5 |
| lgpPwrTopRedundantControlModules The device has a redundant control module installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.7 |
| lgpPwrInputIsolationTransformerInstalled Indicates whether the input isolation transformer is installed. | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.8 |
| lgpPwrStateStaticSwitchType Static switch type (N/A, continous duty, or momentary duty). | scalar | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.7.9 |