lgpPwrLineMeasurementVoltageTHD
LIEBERT-GP-POWER-MIB ·
.1.3.6.1.4.1.476.1.42.3.5.2.3.1.10
Object
The present total harmonic distortion on the AC line voltage.
Context
- MIB
- LIEBERT-GP-POWER-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.5.2.3.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.1 Percent
- Parent
- lgpPwrLineMeasurementEntry
- Table
- lgpPwrLineMeasurementTable
- Siblings
- 20
Syntax
0.1 Percent SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpPwrMeasurementPtIndex This is the index indicating the row of the table
'lgpPwrMeasurementPointTable' for a power measurement point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.1 |
| lgpPwrLineMeasurementCurrentTHD The present total harmonic distortion on the AC line current. | column | 0.1 Percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.11 |
| lgpPwrLineMeasurementKFactorCurrent The present line K Factor. | column | 0.1 K Factor SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.12 |
| lgpPwrLineMeasurementCrestFactorCurrent The present crest factor of the line current. | column | 0.1 Crest Factor SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.13 |
| lgpPwrLineMeasurementPowerFactor The present Power Factor for the line. | column | 0.01 Power Factor SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.14 |
| lgpPwrLineMeasurementPowerFactorTag The present description of the Power Factor for the line. If
Leading, the load is said to be capacitive and the phase of the
current leads the voltage. If Lagging, the load is s… | column | Enumeration | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.15 |
| lgpPwrLineMeasurementMaxVolts The maximum voltage measurement recorded for the indicated source
since the command 'lgpPwrStatisticsReset' was executed. | column | Volt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.16 |
| lgpPwrLineMeasurementMinVolts The minimum voltage measurement recorded for the
indicated source since the command 'lgpPwrStatisticsReset' was
executed. | column | Volt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.17 |
| lgpPwrLineMeasurementVAR The present reactive AC line power of the power source indicated by
'lgpPwrMeasurementPoint'. | column | Volt-Amp-Reactive SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.18 |
| lgpPwrLineMeasurementPercentLoad The present percent load of the AC line power. | column | percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.19 |
| lgpPwrLineMeasurementIndex This is the index indicating the row of the table
'lgpPwrLineMeasurementTable' for a power measurement point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.2 |
| lgpPwrLineMeasurementVolts The present voltage measurement for the indicated source. | column | Volt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.20 |
| lgpPwrLineMeasurementVACapacity The percentage of the apparent power capacity presently being
used on this line. | column | percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.21 |
| lgpPwrMeasurementPoint An OID representing a well known measurement point.
These object identifiers indicate a point or location of power
measurement in a power system. The OID name usually
implies a l… | column | ObjectIdentifier | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.3 |
| lgpPwrLineMeasurementVoltsLL The present Line-to-Line voltage measurement for the indicated
source. The line being measured is given by the
lgpPwrLineMeasurementIndex [1 = AB, 2 = BC, 3 = CA]. | column | Volt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.4 |
| lgpPwrLineMeasurementVoltsLN The present Line-to-neutral voltage measurement for the indicated
source. The line being measured is given by the
lgpPwrLineMeasurementIndex where [1 = A, 2 = B, 3 = C]. | column | Volt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.5 |
| lgpPwrLineMeasurementCurrent The present current measurement for the indicated source. The line
being measured is given by the 'lgpPwrLineMeasurementIndex' where
[1 = A, 2 = B, 3 = C]. | column | Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.6 |
| lgpPwrLineMeasurementCapacity The percentage of the power capacity presently being used on this
line. | column | percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.7 |
| lgpPwrLineMeasurementVA The present apparent AC line power. | column | Volt-Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.8 |
| lgpPwrLineMeasurementTruePower The present AC line power measured in watts. | column | Watt SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.5.2.3.1.9 |