lgpEnvHumidityMeasurementRelTenths
LIEBERT-GP-ENVIRONMENTAL-MIB ·
.1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.50
Object
The measured humidity value.
Context
- MIB
- LIEBERT-GP-ENVIRONMENTAL-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.50- Type
- column
- Access
- readonly
- Status
- current
- Units
- .1 percent Relative Humidity
- Parent
- lgpEnvHumidityEntryRel
- Table
- lgpEnvHumidityTableRel
- Siblings
- 19
Syntax
.1 percent Relative Humidity SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpEnvHumidityIdRel This OID is used as an index to identify a row in the table
'lgpEnvHumidityTableRel'. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.1 |
| lgpEnvHumidityDailyHighTimeMinute The minutes digit of the time corresponding to the daily high
humidity measurement. | column | minutes Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.10 |
| lgpEnvHumidityDailyHighTimeSecond The seconds digit of the time corresponding to the daily high
humidity measurement. | column | seconds Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.11 |
| lgpEnvHumidityDailyLowTimeHour The hours digit of the time corresponding to the daily low humidity measurement. | column | hours Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.12 |
| lgpEnvHumidityDailyLowTimeMinute The minutes digit of the time corresponding to the daily low
humidity measurement. | column | minutes Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.13 |
| lgpEnvHumidityDailyLowTimeSecond The seconds digit of the time corresponding to the daily low humidity measurement. | column | seconds Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.14 |
| lgpEnvHumidityDeadBand The deadband region around the setpoint value
(lgpEnvHumiditySetPoint) where no humidifying or dehumidifying will occur. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.15 |
| lgpEnvHumidifyPropBand The proportional region below the setpoint value
(lgpEnvHumiditySetPoint) where humidifying will be
proportionally controlled. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.16 |
| lgpEnvDehumidifyPropBand The proportional region above the setpoint value
(lgpEnvHumiditySetPoint) where dehumidifying will be
proportionally controlled. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.17 |
| lgpEnvHumidityDescrRel A reference to a humidity description object. The object
referenced should not be accessible, but rather be used
to provide a unique description of the humidity. | column | ObjectIdentifier | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.2 |
| lgpEnvHumidityMeasurementRel The measured humidity value. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.3 |
| lgpEnvHumidityHighThresholdRel The high humidity notification threshold. This is the maximum
value of 'lgpEnvHumidityMeasurementRel' before the agent sends a
notification. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.4 |
| lgpEnvHumidityLowThresholdRel The low humidity notification threshold. This is the minimum
value of 'lgpEnvHumidityMeasurementRel' before the agent sends a
notification. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.5 |
| lgpEnvHumidityHighThresholdRelTenths The high humidity notification threshold. This is the maximum
value of 'lgpEnvHumidityMeasurementRelTenths' before the agent sends a
notification. | column | .1 percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.51 |
| lgpEnvHumidityLowThresholdRelTenths The low humidity notification threshold. This is the minimum
value of 'lgpEnvHumidityMeasurementRelTenths' before the agent sends a
notification. | column | .1 percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.52 |
| lgpEnvHumiditySetPoint The humidity setting used to control the well known humidity
object 'lgpEnvHumidityDescrRel'. This setting may or may not be
the setting used from control. Some systems have the… | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.6 |
| lgpEnvHumidityDailyHigh The daily high relative humidity measurement. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.7 |
| lgpEnvHumidityDailyLow The daily low relative humidity measurement. | column | percent Relative Humidity SNMPv2-SMIInteger32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.8 |
| lgpEnvHumidityDailyHighTimeHour The hours digit of the time corresponding to the daily high
humidity measurement. | column | hours Integer32 | .1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.9 |