slcSystemInternalTempHigh
LANTRONIX-SLC-MIB ·
.1.3.6.1.4.1.244.1.1.6.33
Object
The maximum acceptable internal temperature for the SLC, in Celsius.
Context
- MIB
- LANTRONIX-SLC-MIB
- OID
.1.3.6.1.4.1.244.1.1.6.33- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- Celsius
- Parent
- slcSystem
- Siblings
- 34
Syntax
Celsius SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| slcSystemModel The model of the SLC: SLC8, SLC16, SLC32, SLC48, SLC8008,
SLC8016, SLC8024, SLC8032, SLC8040, SLC8048. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.1 |
| slcSystemLoginBanner The banner displayed after successful login. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.10 |
| slcSystemLogoutBanner The banner displayed after logout. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.11 |
| slcSystemWebTimeout The timeout (in minutes) for web sessions. A value of 0
indicates that timeouts are disabled. | scalar | minutes Integer32 | .1.3.6.1.4.1.244.1.1.6.12 |
| slcSystemWebGadget If enabled, iGoogle Gadget web content is enabled. | scalar | EnabledState | .1.3.6.1.4.1.244.1.1.6.13 |
| slcSystemAction Performs an action on the SLC. A read of this object always
returns the value noAction(1). Setting this object to
rebootSLC(2) will terminate all connections and reboot the
S… | scalar | Enumeration | .1.3.6.1.4.1.244.1.1.6.14 |
| slcSystemSSHPreAuthBanner The banner displayed prior to SSH authentication. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.15 |
| slcSystemSiteRackRow The identifier of the row of racks in a data center
containing the SLC. | scalar | Integer32 | .1.3.6.1.4.1.244.1.1.6.16 |
| slcSystemSiteRackCluster The identifier of the group of racks in a given row
(slcSystemSiteRackRow) containing the SLC. | scalar | Integer32 | .1.3.6.1.4.1.244.1.1.6.17 |
| slcSystemSiteRack The identifier of the rack in a given rack group
(slcSystemSiteRackCluster) containing the SLC. | scalar | Integer32 | .1.3.6.1.4.1.244.1.1.6.18 |
| slcSystemLCDScreens A string describing the enabled LCD screens, in the order they
are displayed. Each screen is separated by a comma. The
possible screens are Current Time, Network, Console, Rel… | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.19 |
| slcSystemSerialNo The serial number of the SLC. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.2 |
| slcSystemLCDUserStrLine1 For the LCD screen User Strings, this is the first line
displayed on the LCD. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.20 |
| slcSystemLCDUserStrLine2 For the LCD screen User Strings, this is the second line
displayed on the LCD. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.21 |
| slcSystemLCDScrolling If enabled, the LCD automatically scrolls through the
enabled screens. | scalar | EnabledState | .1.3.6.1.4.1.244.1.1.6.22 |
| slcSystemLCDScrollDelay If LCD scrolling is enabled (slcSystemLCDScrolling), the
delay in seconds between displaying screens. | scalar | seconds Integer32 | .1.3.6.1.4.1.244.1.1.6.23 |
| slcSystemLCDIdleDelay If LCD scrolling is enabled (slcSystemLCDScrolling), the
number of seconds after keypad input before auto-scrolling
restarts. | scalar | seconds Integer32 | .1.3.6.1.4.1.244.1.1.6.24 |
| slcSystemInternalTemp The internal temperature of the SLC, given in Celsius.
A value of 9999 is returned if an error is encountered
reading the temperature. | scalar | Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.244.1.1.6.25 |
| slcSystemWebProtocol The protocol used by the web server. This setting is no
longer available; the web server is configured to only
support the TLS protocol. | scalar | Enumeration | .1.3.6.1.4.1.244.1.1.6.26 |
| slcSystemWebCipher The strength of the cipher used by the web server. A cipher
with high strength uses 256, 168 or 128 bits; a cipher with
medium strength uses 128 bits; a cipher with low strengt… | scalar | Enumeration | .1.3.6.1.4.1.244.1.1.6.27 |
| slcSystemModelString A string that describes the SLC model:
<Model>-<Power Supply>-<PCCard or USB> | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.28 |
| slcSystemWebGroup The group or groups that may access the web. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.29 |
| slcSystemFWRev The firmware version of the SLC. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.3 |
| slcSystemWebInterface A string describing the interfaces the web is available on;
for example: Eth1,Eth2,PPP. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.30 |
| slcSystemWebBanner The banner on the web home page. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.31 |
| slcSystemInternalTempLow The minimum acceptable internal temperature for the SLC,
in Celsius. | scalar | Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.244.1.1.6.32 |
| slcSystemCalibrateTemp An offset in Celsius for calibrating the internal temperature
of the SLC. | scalar | Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.244.1.1.6.34 |
| slcSystemWebServer If enabled, the web server will run and listen on TCP
ports 80 and 443 (all requests to port 80 are redirected
to port 443). | scalar | EnabledState | .1.3.6.1.4.1.244.1.1.6.35 |
| slcSystemLoadVia The method used for firmware updates. | scalar | Enumeration | .1.3.6.1.4.1.244.1.1.6.4 |
| slcSystemFTPServer The IP Address of the FTP/TFTP server used for firmware
updates, and for saving and restoring configurations. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.244.1.1.6.5 |
| slcSystemFTPPath The path on the FTP server used for firmware updates, and
for saving and restoring configurations. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.6 |
| slcSystemKeypadLock If enabled, the LCD keypad is locked for editing
configuration. The keys can only be used to view settings. | scalar | EnabledState | .1.3.6.1.4.1.244.1.1.6.7 |
| slcSystemTimeZone The time zone of the SLC. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.8 |
| slcSystemWelcomeBanner The banner displayed before the login prompt. | scalar | OctetString | .1.3.6.1.4.1.244.1.1.6.9 |