juniSonetPathTriggerAlarms

Juniper-UNI-SONET-MIB · .1.3.6.1.4.1.4874.2.2.7.2.3.1.7

Object

column r/w Bits
The path alarms that are used in the operational status calculation for
this SONET Path.
    pathLOP     When this bit is set, path LOP is used for operational
                status calculation.  This bit may not be modified.
    pathAIS     When this bit is set, path AIS is used for operational
                status calculation.  This bit may not be modified.
    pathRDI     When this bit is set, path RDI is used for operational
                status calculation.
              
The value of this object defaults to bits 0 and 1 set, indication LOP
and AIS will be used for operational status calculation this SONET
Path.

Context

MIB
Juniper-UNI-SONET-MIB
OID
.1.3.6.1.4.1.4874.2.2.7.2.3.1.7
Type
column
Access
readwrite
Status
current
Parent
juniSonetPathEntry
Table
juniSonetPathTable
Siblings
10

Syntax

Bits

Values & Constraints

Enumerated Values
0pathLOP
1pathAIS
2pathRDI

Related Objects

Sibling Objects