juniAtmBulkCircuitsRowStatus
Juniper-UNI-ATM-MIB ·
.1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4
Object
Controls creation/deletion of entries in this table. Only the values
'createAndGo' and 'destroy' may be SET.
Since none of the VPI/VCI minimum and maximum values have default
values, all these values must be specified before setting RowStatus to
'createAndGo'. The VPI/VCI minimum and maximum values can only be
configured upon creation.
Deleting an entry in this table deletes corresponding entries in
juniAtmProfileOverrideAssignIfCircuitTable.
Context
- MIB
- Juniper-UNI-ATM-MIB
- OID
.1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- juniAtmBulkCircuitsEntry
- Table
- juniAtmBulkCircuitsTable
- Siblings
- 8
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniAtmBulkCircuitsAal5IfIndex The ifIndex of the ATM AAL5 interface on which this bulk virtual
circuit sub-range is created. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.1 |
| juniAtmBulkCircuitsId The integer identifier associated with this ATM bulk virtual circuit
name. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.2 |
| juniAtmBulkCircuitsInstance The unique identifier of the ATM bulk virtual circuit sub-range. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.3 |
| juniAtmBulkCircuitsMinVpi The minimum value of VPI for this circuit sub-range. This value must
be less than or equal to the value of juniAtmBulkCircuitsMaxVpi. | column | ATM-TC-MIBAtmVpIdentifier | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.5 |
| juniAtmBulkCircuitsMaxVpi The maximum value of VPI for this cicuit sub-range. This value must
be equal to or greater than the value of juniAtmBulkCircuitsMinVpi. | column | ATM-TC-MIBAtmVpIdentifier | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.6 |
| juniAtmBulkCircuitsMinVci The minimum value of VCI for this circuit sub-range. This value must
be less than or equal to the value of juniAtmBulkCircuitsMaxVci. | column | ATM-TC-MIBAtmVcIdentifier | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.7 |
| juniAtmBulkCircuitsMaxVci The maximum value of VCI for this circuit sub-range. This value must
be equal to or greater than the value of juniAtmBulkCircuitsMinVci. | column | ATM-TC-MIBAtmVcIdentifier | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.8 |
| juniAtmBulkCircuitsAdminState The administrative status of this circuit sub-range. | column | Juniper-TCJuniEnable | .1.3.6.1.4.1.4874.2.2.8.1.2.5.1.9 |