juniSystemTempProtectionHoldOffTimeRemaining
Juniper-System-MIB ·
.1.3.6.1.4.1.4874.2.2.2.1.9.7
Object
scalar
seconds Integer32
The time remaining, in seconds, before the system enters Thermal Protection mode while the ThermalProtectionStatus is set to inHoldOff. The value decrements every second until it reaches zero, and the status changes to activatedHoldOffExpired. When ThermalProtectionStatus is not inHoldOff or activatedHoldOffExpired, the value is set to the hold off time.
Context
- MIB
- Juniper-System-MIB
- OID
.1.3.6.1.4.1.4874.2.2.2.1.9.7- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- seconds
- Parent
- juniSystemTemperature
- Siblings
- 6
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 0-1200
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniSystemFanCount The maximum number of fan subsystems that may be present in the system.
This is a fixed number for each product type. | scalar | Integer32 | .1.3.6.1.4.1.4874.2.2.2.1.9.1 |
| juniSystemFanTable A table of status of the system's fan subsystems. | table | - | .1.3.6.1.4.1.4874.2.2.2.1.9.2 |
| juniSystemTempCount The maximum number of possible temperature sensors in the system. | scalar | Integer32 | .1.3.6.1.4.1.4874.2.2.2.1.9.3 |
| juniSystemTempTable A table of status of the system's temperature sensors. | table | - | .1.3.6.1.4.1.4874.2.2.2.1.9.4 |
| juniSystemTempProtectionStatus Thermal Protection status:
off - No thermal protection.
monitoring - Monitoring.
inHoldOff - Hold off time has begun.
activate… | scalar | Enumeration | .1.3.6.1.4.1.4874.2.2.2.1.9.5 |
| juniSystemTempProtectionHoldOffTime The time, in seconds, before the system enters Thermal Protection mode
after a critical thermal failure is detected. | scalar | seconds Integer32 | .1.3.6.1.4.1.4874.2.2.2.1.9.6 |