juniERXSysTempProtectionStatusChange
Juniper-ERX-System-MIB ·
.1.3.6.1.4.1.4874.2.2.17.0.7
Object
notification
deprecated
Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime.
Context
- MIB
- Juniper-ERX-System-MIB
- OID
.1.3.6.1.4.1.4874.2.2.17.0.7- Type
- notification
- Status
- deprecated
- Parent
- juniERXSysTrap
- Siblings
- 6
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniERXSysSlotOperStatusChange deprecated Reports a status change for a slot.
This trap is generated on a transition into a stable state (online or
disabled) or on a transition out of online. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.1 |
| juniERXSysPowerStatusChange deprecated Reports a change in the status of a power element. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.2 |
| juniERXSysTempFanStatusChange deprecated Reports a transition between the three states of the fan subsystem.
When the fan subsystem transitions to the failed state the thermal
protection hold off time begins. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.3 |
| juniERXSysTempStatusChange deprecated Reports a change in the temperature status. When the status
transitions to the tooHigh state the system enters thermal protection
mode. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.4 |
| juniERXSysHighMemUtil deprecated Report system memory utilization has met the conditions of
juniERXSysHighMemUtilThreshold. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.5 |
| juniERXSysAbatedMemUtil deprecated Reports system memory utilization has met the conditions of
juniERXSysAbatedMemUtilThreshold. | notification | - | .1.3.6.1.4.1.4874.2.2.17.0.6 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniERXSysTempProtectionStatus deprecated Thermal protection status:
monitoring monitoring
inHoldOff hold off time has begun
activatedHoldOffExpired hold off time has expired, the sy… | scalar | Enumeration | .1.3.6.1.4.1.4874.2.2.17.1.7.3 |
| juniERXSysTempProtectionHoldOffTimeRemaining deprecated The time remaining, in seconds, before the system enters thermal
protection mode while the thermal protection status is set to inHoldOff.
The value decrements every second until i… | scalar | seconds Integer32 | .1.3.6.1.4.1.4874.2.2.17.1.7.5 |