juniERXSysTempFanStatus
Juniper-ERX-System-MIB ·
.1.3.6.1.4.1.4874.2.2.17.1.7.1
Object
scalar
deprecated
Enumeration
Status of fan subsystem.
ok All components operational
warning The fan subsystem has a non-critical failure.
failed The fan subsystem has a critical failure, or has been
removed, and is now non-operational.
Context
- MIB
- Juniper-ERX-System-MIB
- OID
.1.3.6.1.4.1.4874.2.2.17.1.7.1- Type
- scalar
- Access
- readonly
- Status
- deprecated
- Parent
- juniERXSysTemperature
- Siblings
- 4
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | failed |
1 | ok |
2 | warning |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniERXSysTempTable deprecated Table of system temperature sensors.
Sensors are distributed across the chassis, at least one sensor per
populated slot. | table | - | .1.3.6.1.4.1.4874.2.2.17.1.7.2 |
| juniERXSysTempProtectionStatus deprecated Thermal protection status:
monitoring monitoring
inHoldOff hold off time has begun
activatedHoldOffExpired hold off time has expired, the sy… | scalar | Enumeration | .1.3.6.1.4.1.4874.2.2.17.1.7.3 |
| juniERXSysTempProtectionHoldOffTime deprecated The time, in seconds, before the system enters thermal protection mode
after a critical fan subsystem failure is detected. | scalar | seconds Integer32 | .1.3.6.1.4.1.4874.2.2.17.1.7.4 |
| juniERXSysTempProtectionHoldOffTimeRemaining deprecated The time remaining, in seconds, before the system enters thermal
protection mode while the thermal protection status is set to inHoldOff.
The value decrements every second until i… | scalar | seconds Integer32 | .1.3.6.1.4.1.4874.2.2.17.1.7.5 |