jnxoptIfOTNPMFECCurrentDayElapsedTime
JNX-OPT-IF-EXT-MIB ·
.1.3.6.1.4.1.2636.3.73.1.3.3.10.1.11
Object
Time elapsed for current day.
Context
- MIB
- JNX-OPT-IF-EXT-MIB
- OID
.1.3.6.1.4.1.2636.3.73.1.3.3.10.1.11- Type
- column
- Access
- readonly
- Status
- current
- Units
- seconds
- Parent
- jnxoptIfOTNPMFECCurrentDayEntry
- Table
- jnxoptIfOTNPMFECCurrentDayTable
- Siblings
- 11
Syntax
seconds SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| jnxoptIfOTNPMFECCurrentDayType This parameter indicates the parameters for the table are for the
Near End or Far End performance data.
1 - Near End
2 - Far End | column | JnxoptIfOTNType | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.1 |
| jnxoptIfOTNPMCurrentDayAvgFECBERExponent The average bit error rate at receiving side before the FEC
function counted over one second .. exponent. This is the average
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.10 |
| jnxoptIfOTNPMFECCurDaySuspectReason If SuspectedFlag is true, the reson for the PM data being suspect.
0 - not applicable
1 - unknown
2 - new object
3 - clock shift detected
4 - cleared by user
5 - partial data
6 - … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.12 |
| jnxoptIfOTNPMFECCurrentDaySuspectedFlag If true, the data in this entry may be unreliable. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.2 |
| jnxoptIfOTNPMCurrentDayFECCorrectedErr The number of bits corrected by the FEC are counted in the
interval. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.3 |
| jnxoptIfOTNPMCurrentDayFECUncorrectedWords The number of words un-corrected by the FEC are counted over the
Day. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.4 |
| jnxoptIfOTNPMCurrentDayMinFECBERMantissa The minimun bit error rate at receiving side before the FEC
function counted over one second .. mantissa. This is the minimum
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.5 |
| jnxoptIfOTNPMCurrentDayMinFECBERExponent The minimun bit error rate at receiving side before the FEC
function counted over one second .. exponent. This is the minimum
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.6 |
| jnxoptIfOTNPMCurrentDayMaxFECBERMantissa The maximun bit error rate at receiving side before the FEC
function counted over one second .. mantissa. This is the maximum
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.7 |
| jnxoptIfOTNPMCurrentDayMaxFECBERExponent The maximun bit error rate at receiving side before the FEC
function counted over one second .. exponent. This is the maximum
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.8 |
| jnxoptIfOTNPMCurrentDayAvgFECBERMantissa The average bit error rate at receiving side before the FEC
function counted over one second .. mantissa. This is the average
PreFEC BER in the current 24hour period. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2636.3.73.1.3.3.10.1.9 |