cmmCoherentModuleMonitorEntry
IPI-CMM-COHERENT-MIB ·
.1.3.6.1.4.1.36673.100.1.15.1.3.1
Object
row
A optical entry containing interface related objects for a particular port..
Context
- MIB
- IPI-CMM-COHERENT-MIB
- OID
.1.3.6.1.4.1.36673.100.1.15.1.3.1- Type
- row
- Status
- current
- Parent
- cmmCoherentModuleMonitorTable
- Table
- cmmCoherentModuleMonitorTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmmModuleTempHighAlarmThreshold Module Temperature High Alarm threshold in C.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.1 |
| cmmModuleTempHighWarnThreshold Module Temperature High Warn Threshold in C.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.2 |
| cmmModuleTempLowWarnThreshold Module Temperature Low Warn Threshold in C.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.3 |
| cmmModuleTempLowAlarmhreshold Module Temperature Low Alarm threshold in C.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.4 |
| cmmModuleVoltHighAlarmThreshold Module Voltage High Alarm threshold in V.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.001 V Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.5 |
| cmmModuleVoltHighWarnThreshold Module Voltage High Warn Threshold in v.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.001 V Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.6 |
| cmmModuleVoltLowWarnThreshold Module Voltage Low Warn Threshold in V.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.001 V Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.7 |
| cmmModuleVoltlowAlarmThreshold Module Volatge Low Alarm threshold in C.
-100003 indicates device not ready
-100002 indicates Not applicable
'-100001' indicates internal error | column | 0.001 V Integer32 | .1.3.6.1.4.1.36673.100.1.15.1.3.1.8 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|