configDirectMaxReservedBw
IBM-ELAN-MIB ·
.1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.5
Object
column
mandatory
r/w
Integer32
Defines the maximum acceptable Sustained Cell Rate (SCR) for a Configuration Direct VCC; if SCR is not specified on the incoming call, then this parameter defines the maximum acceptable Peak Cell Rate (PCR) for a Configuration Direct VCC with reserved bandwidth. This parameter is applied to both forward and backward directions. Calls received with Traffic Parameters specifying higher rates will be released. If SCR is specified on the incoming call, the call will not be rejected due to the PCR or Maximum Burst Size. The constraint imposed by this parameter is not applicable to BEST EFFORT connections.
Context
- MIB
- IBM-ELAN-MIB
- OID
.1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.5- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- ibmLecsConfEntry
- Table
- ibmLecsConfTable
- Siblings
- 8
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-155000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lecsUseBurnedInEsi mandatory Specifies whether a MAC Address burned into the ATM
device should be used as the End System Identifier
component of the LECS ATM Address. | column | SNMPv2-TC-v1TruthValue | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.1 |
| lecsConfiguredEsi mandatory Locally Administered End System Identifier that is to be
used as the ESI component of the LECS's ATM Address. | column | NWAYSMSS-MIBAtmPrivateAddrEsi | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.2 |
| lecsConfiguredSelector mandatory Specifies value to be used as Selector field component
of LECS's ATM address. | column | NWAYSMSS-MIBAtmSelector | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.3 |
| lecsValidateBestEffortPcr mandatory When false, Best Effort Configuration Direct VCCs will
be accepted without regard to the signalled forward
Peak Cell Rate (PCR). When true, Best Effort VCCs
will be rejected if t… | column | SNMPv2-TC-v1TruthValue | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.4 |
| atmDevLineSpeed mandatory Line Speed of LECS ATM Device.
This should not exposed to the user. | column | - | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.6 |
| idleVccTime mandatory When the maximum number of VCCs is exceeded at
the LECS, VCCs are released (see lecsMaxVccs).
All active VCCs at the LECS are scanned.
If a VCC has been inactive for this length o… | column | Integer32 | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.7 |
| lecsMaxVccs mandatory This is the maximum number of simultaneous VCCs
supported by the LECS. If this number is exceeded,
then VCCs will be released (see idleVccTime). | column | Integer32 | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.8 |
| lecsDomainName mandatory This is the name to associate with the Domain of the LECS | column | OctetString | .1.3.6.1.4.1.2.6.118.1.2.1.4.3.1.1.1.9 |