aixAgentExeCommand
IBM-AIX-MIB ·
.1.3.6.1.4.1.2.6.191.1.1.3
Object
scalar
r/w
Enumeration
The variable is used to trigger the execution of the command in seCommandString. The result is stored by seCmdResult, and the output is stored by aixAgentCmdOutTable. The normal state of this object is 2(default). When set to 1(trigger), the command stored in aixAgentCmdString will be run. trigger(1) - when the value of the variable is set to trigger(1), the command stored at aixAgentCmdString will be executed. default(2) - is the default value.
Context
- MIB
- IBM-AIX-MIB
- OID
.1.3.6.1.4.1.2.6.191.1.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- aixAgent
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | trigger |
2 | default |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| aixAgentAction This variable is used to trigger an action on the
agent itself . 5 (running) is the normal state.
When set, this variable triggers the agent
to do the following:
res… | scalar | Enumeration | .1.3.6.1.4.1.2.6.191.1.1.1 |
| aixCPUPollInterval The polling interval for CPU utilization. This variable works
together with the general polling interval
aixAgentPollInterval. Its default value is zero.
1) If aixAgentPollInter… | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.10 |
| aixVgPollInterval The polling interval for volume groups. This variable works
together with the general polling interval
aixAgentPollInterval. Its default value is zero.
1) If aixAgentPollInterv… | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.11 |
| aixPagePollInterval The polling interval for paging spaces. This variable works
together with the general polling interval
aixAgentPollInterval. Its default value is zero.
1) If aixAgentPollInterva… | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.12 |
| aixLFPollInterval The polling interval for login failure. This variable works
together with the general polling interval
aixAgentPollInterval. Its default value is zero.
1) If aixAgentPollInterva… | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.13 |
| aixAgentCmdString This string represents a runnable
command on AIX with its parameters.
Once the command string is set, the system can
trigger the execution of the command by
setting the value o… | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2.6.191.1.1.2 |
| aixAgentCmdResult This object stores the output result of executing
the command stored by aixAgentCmdString. | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.4 |
| aixAgentPollInterval The poll interval(in seconds) used by the agent. The default
value is zero. This value is used to define the minimum time
interval during which the subagent must update an obje… | scalar | seconds Integer32 | .1.3.6.1.4.1.2.6.191.1.1.5 |
| aixPollEnable Enables or disables polling. It may change
the following polling interval variables:
aixAgentPollInterval
aixFsPollInterval
aixCPUPollInterval
aixVgPollInterval
aixPagePol… | scalar | Enumeration | .1.3.6.1.4.1.2.6.191.1.1.6 |
| aixLastTrapMsg This object holds the most recent trap message sent
from the subagent. Its default value is set to NULL. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2.6.191.1.1.7 |
| aixAgentCmdOutTable The output from the execution of the command stored in
aixAgentCmdString | table | - | .1.3.6.1.4.1.2.6.191.1.1.8 |
| aixFsPollInterval The polling interval for file systems. This variable works
together with the general polling interval
aixAgentPollInterval. Its default value is zero.
1) If aixAgentPollInterva… | scalar | Integer32 | .1.3.6.1.4.1.2.6.191.1.1.9 |