IBM-AIX-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
22
Rows
22
Columns
178
aixAgentCmdOutTable
table.1.3.6.1.4.1.2.6.191.1.1.8
·
1 row entry
·
2 columns
The output from the execution of the command stored in aixAgentCmdString
An entry of the agent command output table
Indexes
aixAgentCmdOutIndex
| Column | Syntax | OID |
|---|---|---|
|
aixAgentCmdOutput
After the command stored in aixAgentCmdString is run,
each line of the output is stored in one entry of this table. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.1.1.8.1.1 |
|
aixAgentCmdOutIndex
Index of the table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.1.1.8.1.2 |
aixVgTable
table.1.3.6.1.4.1.2.6.191.2.1.2
·
1 row entry
·
9 columns
A table of defined volume groups. The number of entries depends on the configuration of the system. On AIX, a volume group is a collection of 1 to 32 physical volumes of varying size and type with a system-wide unique name of up to 15 characters. Each system can have one to 255 volume groups configured. This table will be refreshed at least with each poll interval.
An entry of vgTable. Each entry contains all
the attributes of each volume group.
the attributes of each volume group.
Indexes
aixVgIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
aixVgName
The name of a volume group. The name must be
system-wide unique and can range from 1 to 15 characters |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.1.2.1.1 |
||||||||
|
aixVgIdentifier
It is a series of numbers(e.g. 0038455182a7b5f6)
to identify the volume group. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.1.2.1.2 |
||||||||
|
aixVgState
State of the volume group. If the volume group is
activated with the varyonvg command, the state is either active/complete (indicating all physical volumes are active) or active/partial (indicating some physical vol… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.1.2.1.3 |
||||||||
|
aixVgSize
The total size of the volume group in megabytes.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.4 |
||||||||
|
aixVgFree
The available size of the volume group in megabytes.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.5 |
||||||||
|
aixVgCurNumLVs
The number of logical volumes currently in the
volume group. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.6 |
||||||||
|
aixVgOpenLVs
Number of logical volumes within the volume group
that are currently open. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.7 |
||||||||
|
aixVgActivePVs
The number of active physical voulmes currently in
the volume group. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.8 |
||||||||
|
aixVgIndex
The columnar index for the vgTable.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.2.1.2.1.9 |
aixLvTable
table.1.3.6.1.4.1.2.6.191.2.2.1
·
1 row entry
·
7 columns
A logical volume is a collection of logical partitions made up of physical partitions, all contained in a single volume group. Logical volumes are expandable and can span several physical volumes in a volume group. Because it is very slow to get the data in the table, no data may be returned from the snmp agent.
An entry of lvTable
Indexes
aixLvIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aixLvName
Logical volume names must be system-wide unique and
can range from 1 to 15 characters. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.2.1.1.1 |
||||||||||||||
|
aixLvNameVG
Name of the volume group the logical volume belongs to.
Volume group names must be unique system wide and can range from 1 to 15 characters. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.2.1.1.2 |
||||||||||||||
|
aixLvType
Logical volume type. The type may be boot, jfslog,
jfs, and paging. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.2.1.1.3 |
||||||||||||||
|
aixLvMountPoint
File system mount point for the logical volume,
if applicable. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.2.1.1.4 |
||||||||||||||
|
aixLvSize
The size of the logical volume in PPS.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.2.1.1.5 |
||||||||||||||
|
aixLvState
The status of the logical volume. It may be open/syncd,
open/stale, close/syncd, close/stale or undefined. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.2.1.1.6 |
||||||||||||||
|
aixLvIndex
The columnar index for the lvTable.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.2.2.1.1.7 |
aixPvTable
table.1.3.6.1.4.1.2.6.191.2.3.1
·
1 row entry
·
7 columns
A physical volume is a read-write disk physically attached to a computer, with a permanently assigned system wide unique identifier. They are added to a volume group with the extendvg command and removed from a volume group with the reducevg command. When added to the volume group, physical volumes are partitioned into contiguous, equal-sized units of space called physical partitions.
An entry of pvTable
Indexes
aixPvIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
aixPvName
The name of the physical volume. Physical volume names
are typically in the form hdiskx where x is a system wide unique number. This name is assigned when the disk is detected for the first time on a system startup or… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.3.1.1.1 |
||||||||
|
aixPvNameVG
The volume group which is assigned to the physical
volume. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.3.1.1.2 |
||||||||
|
aixPvState
State of the physical volume. If the volume group that
contains the physical volume is varied on with the varyonvg command, the state is active , missing , or removed . If the physical volume is varied off with the … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.3.1.1.3 |
||||||||
|
aixPvSize
Total size of the physical volume in megabytes.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.3.1.1.4 |
||||||||
|
aixPvFree
Available size of the physical volume in megabytes
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.3.1.1.5 |
||||||||
|
aixPvNumLVs
Number of logical volumes using the physical volume.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.3.1.1.6 |
||||||||
|
aixPvIndex
The columnar index for the pvTable.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.2.3.1.1.7 |
aixPageTable
table.1.3.6.1.4.1.2.6.191.2.4.2
·
1 row entry
·
8 columns
A paging space is fixed-disk storage for information that is resident in virtual memory, but is not currently being accessed. When the amount of free real memory in the system is low, programs or data that have not been used recently are moved from real memory to paging space in order to free real memory for other activities. This table will be refreshed at least with each poll interval.
An entry of the pageTable Table
Indexes
aixPageIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
aixPageName
The name of the paging space. It is assigned by the
system automatically when it is created. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.4.2.1.1 |
||||||
|
aixPageNameVG
Specifies the volume group within which the logical
volume for the paging space is created. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.4.2.1.2 |
||||||
|
aixPageNamePV
Specifies the physical volume of the volume group.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.2.4.2.1.3 |
||||||
|
aixPageSize
The size of the paging space.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.2.4.2.1.4 |
||||||
|
aixPagePercentUsed
The used percentage of the paging space.
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2.6.191.2.4.2.1.5 |
||||||
|
aixPageStatus
Status of the paging space.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.4.2.1.6 |
||||||
|
aixPageType
The type of paging space.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.2.4.2.1.7 |
||||||
|
aixPageIndex
The columnar index for the pageTable.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.2.4.2.1.8 |
aixPrtQueTable
table.1.3.6.1.4.1.2.6.191.3.1.1
·
1 row entry
·
10 columns
The print queue table. If several devices are attached to one queue, there are several entries whose keys are queue name and device name.
An entry for a queue in the print queue table.
Indexes
aixPrtQueIndex
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aixPrtQueName
The name of the queue .
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.1 |
||||||||||||||||||||
|
aixPrtQueDevice
Print Queue device
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.2 |
||||||||||||||||||||
|
aixPrtQueStatus
ready(1) indicates that virtual device is up.
running(2) indicates that virtual device is running a job. waiting(3) indicates that virtual device is could not open and is waiting on a device. off(4) indicates that … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.3.1.1.1.3 |
||||||||||||||||||||
|
aixPrtQueAction
A control variable used to trigger an action on a queue
in the printer table. When read, this variable always returns the most recent value that it was previously set to. If it has not been set since the last initia… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.3.1.1.1.4 |
||||||||||||||||||||
|
aixPrtQueDescipline
Specifies the order of print jobs in the queue.
For example, the discipline may be first come first servei(fcfs) or shrtest job next (sjn). The selected queuing discipline applies to all printers associated with the p… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.5 |
||||||||||||||||||||
|
aixPrtQueAcctFile
Specify the full path name of an existing file where
accounting data for this print queue can be logged. If account is not wanted, it is set to FALSE. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.6 |
||||||||||||||||||||
|
aixPrtQueHost
Specifies the full path name of an existing file
where accounting data for this print queue can be logged. If accounting is not wanted, FALSE is specified. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.7 |
||||||||||||||||||||
|
aixPrtQueRQ
Specifies the remote queue name. If the queue is
defined on the local host, NULL string value will be assigned. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.3.1.1.1.8 |
||||||||||||||||||||
|
aixPrtQueJobNum
the job number of currently running job in the queue.
If the queue is down, the job number of the currently running job will be zero. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.3.1.1.1.9 |
||||||||||||||||||||
|
aixPrtQueIndex
The columnar index for the aixPrtQueTable.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.3.1.1.1.10 |
aixUsrTable
table.1.3.6.1.4.1.2.6.191.4.1.1
·
1 row entry
·
13 columns
List of users.
An entry in the users table.
Indexes
aixUsrIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aixUsrName
Specifies a string that identifies this user account
on the system. A user name contains a string of one to eight bytes. They can be letters, numbers, and some special characters in the user name. The following restric… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.1.1.1.1 |
||||||||||
|
aixUsrID
Defines a unique decimal integer string to associate
with this user account on the system. It is strongly recommended to let the system generate the user to incorporate all the security restrictions and conventions th… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2.6.191.4.1.1.1.2 |
||||||||||
|
aixUsrHome
The user home directory.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.1.1.1.3 |
||||||||||
|
aixUsrShell
The user's initial shell. On AIX, it is also called
initial program. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.1.1.1.4 |
||||||||||
|
aixUsrLocalLogin
Indicates whether the user can log into the system
with the login command locally. default value is true(1) |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.4.1.1.1.5 |
||||||||||
|
aixUsrRemoteLogin
Indicates whether the user can log into the system
with the login command. For example, if this is set to false, the user can not login with the telnet remotely. default value is true(1). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.4.1.1.1.6 |
||||||||||
|
aixUsrPasswdMaxAge
Defines the maximum age (in weeks) for the user's
password. When the password reaches this age, the system requires it to be changed before the user can login again. The value is a decimal integer string. If 0 is spe… |
Integer32r/w Constraints: range: 0-52 |
.1.3.6.1.4.1.2.6.191.4.1.1.1.7 |
||||||||||
|
aixUsrStatus
The user status. Determines the status of the user.
Changing this variable will affect the user. 'locked(2)' is synonymous with 'disabled(3)', and unlocked(1) is the same as enabled(4). Default value is unlocked(1). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.4.1.1.1.8 |
||||||||||
|
aixUsrGroups
Lists the groups to which the user belongs seperated by
the \',\' delimiter. The first on group on the list is the primary group. Groups are collections of users that can share access authority to protected resources.… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.1.1.1.9 |
||||||||||
|
aixUsrAllowableAttempts
Number of failed logins times before the user account
is locked. Default value is 0. Zero or negative value indicates no limit exists. |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2.6.191.4.1.1.1.10 |
||||||||||
|
aixUsrResetLoginCount
After the number of unsuccessful login attempts
defined by aixUsrAllowableAttempts, the user will not be able to log in until the user's unsuccessful_login_count attribute in /etc/security/lastlog to be less than th… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.4.1.1.1.11 |
||||||||||
|
aixUsrPrimaryGroup
The primary group that the user belongs to .
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.1.1.1.12 |
||||||||||
|
aixUsrIndex
The index of the user table .
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.4.1.1.1.13 |
aixGrpTable
table.1.3.6.1.4.1.2.6.191.4.2.1
·
1 row entry
·
6 columns
List of groups.
An entry in the group table.
Indexes
aixGrpIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixGrpIndex
The index of the group table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.4.2.1.1.1 |
||||
|
aixGrpName
Specifies the string that identifies a collection
of system users that can access and work with protected resources. The system uses groups to control access to files and resources by users who do not own them. When… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.2.1.1.2 |
||||
|
aixGrpID
The system assigns a unique ID associated to the
group name. The group IDs are stored in the /etc/group file. |
Integer32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.2.6.191.4.2.1.1.3 |
||||
|
aixGrpAdminGroup
Indicates if the group is an administrative group.
Only the root user can modify the attributes of an administrative group. This field is displayed with False or True as its value. True indicates that group is an ad… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.4.2.1.1.4 |
||||
|
aixGrpUsrList
the users who are in this group.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.2.1.1.5 |
||||
|
aixGrpAdmList
The administrator list for this group .
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.4.2.1.1.6 |
aixSubSysTable
table.1.3.6.1.4.1.2.6.191.5.1.2
·
1 row entry
·
5 columns
A table of subsystems.
An entry in the subsystem table
Indexes
aixSubSysIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixSubSysName
The name of the subsystem.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.1.2.1.1 |
||||
|
aixSubSysGroup
A subsystem group is a group of any specified
subsystems. Grouping subsystems together allows control over several subsystems at the same time. Examples of subsystem groups are TCP/IP, SNA Services, Network Informat… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.1.2.1.2 |
||||
|
aixSubSysPID
The process ID of the subsystem. When the subsystem
is inoperative, the PID is zero. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.5.1.2.1.3 |
||||
|
aixSubSysStatus
The status of the subsystem. When it is active(1),
it can be stopped by setting the status to 2. Or when it is inoperative(2), it can be started by setting the status to 1. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.5.1.2.1.4 |
||||
|
aixSubSysIndex
The index of the subsystem table.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.5.1.2.1.5 |
aixSubSrvTable
table.1.3.6.1.4.1.2.6.191.5.2.2
·
1 row entry
·
6 columns
A table of subservers. A subserver is a program or process that belongs to a subsystem. A subsystem can have multiple subservers and is responsible for starting, stopping, and providing status of the subservers.
An entry in the subserver table.
Indexes
aixSubSrvIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixSubSrvName
the subserver name.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.2.2.1.1 |
||||
|
aixSubSrvDescr
The description of the subserver.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.2.2.1.2 |
||||
|
aixSubSrvCommand
The command to start the subserver.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.2.2.1.3 |
||||
|
aixSubSrvStatus
The status of the subserver.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.5.2.2.1.4 |
||||
|
aixSubSrvSubsys
the subsystem name which the subserver belongs to.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.5.2.2.1.5 |
||||
|
aixSubSrvIndex
The index of the subserver table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.5.2.2.1.6 |
aixFsTable
table.1.3.6.1.4.1.2.6.191.6.2
·
1 row entry
·
11 columns
The file system table. This table will be refreshed at least with each poll interval.
An entry of the file system table
Indexes
aixFsIndex
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aixFsIndex
The index of the file system table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.6.2.1.1 |
||||||||||||||||||||||
|
aixFsName
The name of the file system.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.6.2.1.2 |
||||||||||||||||||||||
|
aixFsMountPoint
Specifies the mount point, which is the directory
where the file system is available or will be made available. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.6.2.1.3 |
||||||||||||||||||||||
|
aixFsType
The file system type. The type may be JFS(Journal
File System), JFS2 (extented JFS), AFS, DFS, cashefs, autofs, procfs, cdrfs (CDROM file system), NFS(Network File System), NFS3 (NFSv3 file system) |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.6.2.1.4 |
||||||||||||||||||||||
|
aixFsSize
The size for this file system in megabytes.
|
megabytesInteger32r/w Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.6.2.1.5 |
||||||||||||||||||||||
|
aixFsFree
Total number of megabytes free in file system.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.6.2.1.6 |
||||||||||||||||||||||
|
aixFsNumINodes
Total number of i-nodes on this file system.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.6.2.1.7 |
||||||||||||||||||||||
|
aixFsUsedInodes
The used number of Inodes in the file system.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.6.2.1.8 |
||||||||||||||||||||||
|
aixFsStatus
The status of the file system. It is either mounted(1)
or unmounted(2). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.6.2.1.9 |
||||||||||||||||||||||
|
aixFsExecution
The variable is used to trigger the mount action
on unmounted file system and unmount action on mounted file system. This state can only change from mount to unmount or unmount to mount. Its normal status is other(1).… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.6.2.1.10 |
||||||||||||||||||||||
|
aixFsResultMsg
The execution result message of mounting or
umounting command. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.6.2.1.11 |
aixProcTable
table.1.3.6.1.4.1.2.6.191.7.2
·
1 row entry
·
10 columns
The Process Table.
Each entry contains information about a process
running on the system.
running on the system.
Indexes
aixProcPID
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aixProcPID
The process ID (pid) of the process.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.1 |
||||||||||||||
|
aixProcUID
The user ID of the process owner.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.2 |
||||||||||||||
|
aixProcPPID
The process ID of the parent process.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.3 |
||||||||||||||
|
aixProcGroup
Indicates the effective group ID of the process.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.4 |
||||||||||||||
|
aixProcPriority
The priority of the process or kernel thread,
higher numbers mean lower priority. |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.5 |
||||||||||||||
|
aixProcCMD
The command name of the process.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.7.2.1.6 |
||||||||||||||
|
aixProcCPU
CPU utilization of process or thread, incremented
each time the system clock ticks and the process or thread is found to be running. Large values indicate a CPU intensive process and results in lower process priority… |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.7.2.1.7 |
||||||||||||||
|
aixProcStart
The start time of the process.
|
SNMPv2-SMITimeTicks Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2.6.191.7.2.1.8 |
||||||||||||||
|
aixProcStatus
For processes:
(1)O Nonexistent (2)A Active (3)W Swapped (4)I Idle (waiting for startup) : (5)Z Canceled (6)T Stopped |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.7.2.1.9 |
||||||||||||||
|
aixProcTTY
Indicates the controlling terminal name of the
process. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.7.2.1.10 |
aixLoginUserTable
table.1.3.6.1.4.1.2.6.191.8.3
·
1 row entry
·
5 columns
loginUserTable contains users who are logged in currently.
An entry of loginUserTable
Indexes
aixLoginUserIndex
| Column | Syntax | OID |
|---|---|---|
|
aixLoginUserName
The user name. If the user name is unknown,
its value is UNKNOWN_U. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.8.3.1.1 |
|
aixLoginUserTTY
The terminal tty name.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.8.3.1.2 |
|
aixLoginUserHost
The IP address of the machine the user tried to
log onto the system from. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.8.3.1.3 |
|
aixLoginUserDateAndTime
The date and time when the user logged in.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.8.3.1.4 |
|
aixLoginUserIndex
Index for the table
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.8.3.1.5 |
aixPrinterTable
table.1.3.6.1.4.1.2.6.191.9.1.1
·
1 row entry
·
8 columns
A table of defined printers/plotters. On AIX, the printer is defined, used and dealt with in the same way as the plotter. The number of entries depends on the configuration of the system such as the serial or parallel port number.
An entry of printerTable. Each entry contains all
attributes of a defined printer or plotter.
attributes of a defined printer or plotter.
Indexes
aixPrinterIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixPrinterName
When a printer or plotter device is added to the
system, a name is automatically assigned to the device. On AIX, this name is in the format of lpx, for example, lp0, lp1. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.1 |
||||
|
aixPrinterIndex
The index of the printer table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.1.1.1.2 |
||||
|
aixPrinterType
This is the type of the printer/plotter. The type
can be the defined printer/plotter name such as hplj-8100 which represents Hewlett-Packard LaserJet 8100, or opp for Other parallel printer, or osp for other seri… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.3 |
||||
|
aixPrinterInterface
The printer/plotter interface with the computer. Its
value can be parallel, rs232, or rs422. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.4 |
||||
|
aixPrinterStatus
Indicates the current status of the device. Possible
values are available(1), indicating that the device is configured in the system and ready to use; and defined(2), indicating that the device is defined to the syste… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.1.1.1.5 |
||||
|
aixPrinterDescr
The description for the printer/plotter.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.6 |
||||
|
aixPrinterLocation
Location codes of 00-00-S1-00 or 00-00-S2-0 indicate
the printer or plotter device is connected to the standard I/O serial ports s1 or s2. A location code of 00-00-0P-00 indicates that the parallel printer is connec… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.7 |
||||
|
aixPrinterPortNumber
The printer port number. This indicates the port on
an adapter card or asynchronous distribution box to which the printer or plotter is connected. The value must be in the range 0 through 7 for an 8-port adapter car… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.1.1.1.8 |
aixTapeDrvTable
table.1.3.6.1.4.1.2.6.191.9.2.1
·
1 row entry
·
14 columns
A table of defined tape drives. The number of entries depends on the configuration of the system.
An entry in the aixTapeDrvTable. Each entry contains all
the attributes of a tape drive.
the attributes of a tape drive.
Indexes
aixTapeDrvIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixTapeDrvName
Identifies the logical name of the device. When a
tape drive is added or defined in the system, a name is automatically assigned to the device. The format of the name looks like rmt0. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.1 |
||||
|
aixTapeDrvIndex
The index of the tape drive table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.2.1.1.2 |
||||
|
aixTapeDrvType
Identifies the predefined device type of the tape
drive. For example, 4mm2gb2 is a scsi 2.0 GB 4mm Tape Drive. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.3 |
||||
|
aixTapeDrvInterface
Identifies the type of tape drive interface. This is
the same as the predefined device subclass of the device. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.4 |
||||
|
aixTapeDrvStatus
Indicates the current status of the tape drive.
Possible values are available (1), indicating that the tape drive is configured in the system and ready to be used, and defined(2), indicating that the tape drive is d… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.2.1.1.5 |
||||
|
aixTapeDrvDescr
Provides a short text description of the tape drive
device. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.6 |
||||
|
aixTapeDrvLocation
For all SCSI devices, including disks, CD-ROMs,
read/write optical drives, tapes, target mode, and initiator devices, the location code format is AA-BB-CC-S,L. The AA-BB fields identify the location code of the SCSI… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.7 |
||||
|
aixTapeDrvBlkSize
Indicates the block size to use when reading or
writing to the tape. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.2.1.1.8 |
||||
|
aixTapeDrvManufacturerName
The name of the manufacturer of the tape drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.9 |
||||
|
aixTapeDrvModelName
The model name of the tape drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.10 |
||||
|
aixTapeDrvSN
The tape driver serial number.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.11 |
||||
|
aixTapeDrvPN
The tape driver part number.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.12 |
||||
|
aixTapeDrvFRU
The tape drive FRU number (Field Replaceable Unit).
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.13 |
||||
|
aixTapeDrvEC
The tape drive EC (Engineering Change).
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.2.1.1.14 |
aixHdTable
table.1.3.6.1.4.1.2.6.191.9.3.1
·
1 row entry
·
15 columns
A table of defined hard disks. The number of entries depends on the configuration of the system.
An entry in hdTable. Each entry contains all
the attributes of the individual hard disk.
the attributes of the individual hard disk.
Indexes
aixHdIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixHdName
Identifies the logical name of the disk device.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.1 |
||||
|
aixHdIndex
The index for the hard disk table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.3.1.1.2 |
||||
|
aixHdType
Identifies the predefined device type of the disk.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.3 |
||||
|
aixHdSize
The size in megabytes of the hard disk.
|
megabytesInteger32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.3.1.1.4 |
||||
|
aixHdInterface
Identifies the type of disk interface. This is
the same as the predefined device subclass of the disk. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.5 |
||||
|
aixHdStatus
Indicates the current status of the disk device.
Possible values are available(1), indicating that the disk device is configured in the system and ready to be used, and defined(2), indicating that the disk device is… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.3.1.1.6 |
||||
|
aixHdLocation
For all SCSI devices, including disks, CD-ROMs,
read/write optical drives, tapes, target mode, and initiator devices, the location code format is AA-BB-CC-S,L. The AA-BB fields identify the location code of the SCSI… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.7 |
||||
|
aixHdIdentifier
Displays the unique physical volume identifier
of the physical volume of a disk. If the disk is not a physical volume, this field value will be none. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.8 |
||||
|
aixHdDescr
Provides a short text description of the disk device.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.9 |
||||
|
aixHdManufacturerName
The name of the manufacturer of the hard drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.10 |
||||
|
aixHdModelName
The Model Name of the hard drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.11 |
||||
|
aixHdSN
The hard driver serial number.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.12 |
||||
|
aixHdPN
The hard driver part number.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.13 |
||||
|
aixHdFRU
The hard drive FRU number (Field Replaceable Unit).
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.14 |
||||
|
aixHdEC
The hard drive Engineering Change.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.3.1.1.15 |
aixMemTable
table.1.3.6.1.4.1.2.6.191.9.4.1
·
1 row entry
·
5 columns
A table of defined physical memory. The number of entries depends on the configuration of the system.
An entry in the memory table .
Indexes
aixMemIndex
| Column | Syntax | OID |
|---|---|---|
|
aixMemName
The name of the memory. For example, it may
be mem0. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.4.1.1.1 |
|
aixMemIndex
The index for the memory table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.4.1.1.2 |
|
aixMemLocation
The memory location code. An example is 00-00.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.4.1.1.3 |
|
aixMemSize
The size of the physical memory in megabytes.
|
megabytesInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.9.4.1.1.4 |
|
aixMemDescr
The description of memory
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.4.1.1.5 |
aixCdromTable
table.1.3.6.1.4.1.2.6.191.9.5.1
·
1 row entry
·
12 columns
A table of all defined cdroms.
An entry in the cdrom table .
Indexes
aixCdromIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixCdromName
Identifies the logical name of the CD-ROM drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.1 |
||||
|
aixCdromIndex
The index for the CD-ROM table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.5.1.1.2 |
||||
|
aixCdromType
Identifies the predefined device type of the
CD-ROM drive. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.3 |
||||
|
aixCdromInterface
Identifies the type of drive interface. This is the
same as the predefined device subclass of the CD-ROM drive. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.4 |
||||
|
aixCdromDescr
Provides a short text description of the CD-ROM
drive device. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.5 |
||||
|
aixCdromStatus
Indicates the current status of the CD-ROM drive.
Possible values are available(1), indicating that the CD-ROM drive is configured in the system and ready to be used, and defined(2), indicating that the drive is defi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.5.1.1.6 |
||||
|
aixCdromLocation
For all SCSI devices, including disks, CD-ROMs,
read/write optical drives, tapes, target mode, and initiator devices, the location code format is AA-BB-CC-S,L. The AA-BB fields identify the location code of the SCSI… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.7 |
||||
|
aixCdromManufacturerName
The name of the manufacturer of the cdrom drive.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.8 |
||||
|
aixCdromModelName
The cdrom driver model name.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.9 |
||||
|
aixCdromPN
The cdrom driver part number.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.10 |
||||
|
aixCdromFRU
The cdrom drive FRU (Field Replaceable Unit).
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.11 |
||||
|
aixCdromEC
The cdrom drive Engineering Change.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.5.1.1.12 |
aixScsiTable
table.1.3.6.1.4.1.2.6.191.9.6.1
·
1 row entry
·
6 columns
A table of SCSI adapters.
An entry of the SCSI adapter .
Indexes
aixScsiIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixScsiName
Identifies the logical name of the adapter.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.6.1.1.1 |
||||
|
aixScsiIndex
The index for the scsi adapter table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.6.1.1.2 |
||||
|
aixScsiDescr
Defines a short text description of the adapter.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.6.1.1.3 |
||||
|
aixScsiStatus
Indicates the current status of the adapter.
Possible values are available, indicating that the adapter is configured in the system and ready to be used, and defined, indicating that the adapter is defined on the s… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.6.1.1.4 |
||||
|
aixScsiLocation
The location code for the SCSI adapter. An example
is 04-C0. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.6.1.1.5 |
||||
|
aixScsiAdapterID
Specifies the SCSI ID value which the adapter
will use when sending SCSI commands as an initiator device, and, if target mode is supported, specifies the SCSI ID the adapter will respond to when acting as a target d… |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.2.6.191.9.6.1.1.6 |
aixProcessorTable
table.1.3.6.1.4.1.2.6.191.9.7.1
·
1 row entry
·
5 columns
A table of processors.
An entry of the Processor .
Indexes
aixProcessorIndex
| Column | Syntax | OID |
|---|---|---|
|
aixProcessorName
Identifies the logical name of the processor.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.7.1.1.1 |
|
aixProcessorIndex
The index for the processor table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.7.1.1.2 |
|
aixProcessorType
Defines the model type of the processor. For example:
PowerPC_604e |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.7.1.1.3 |
|
aixProcessorDescr
Defines a short text description of the processor.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.7.1.1.4 |
|
aixProcessorSpeed
The speed of the processor in hertz.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.7.1.1.5 |
aixNetworkTable
table.1.3.6.1.4.1.2.6.191.9.8.1
·
1 row entry
·
7 columns
A table of Network adapters.
An entry of the Network adapter .
Indexes
aixNetworkIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixNetworkName
Identifies the logical name of the network adapter.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.8.1.1.1 |
||||
|
aixNetworkIndex
The index for the network adapter table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.8.1.1.2 |
||||
|
aixNetworkType
The type of the network adapter. An example
is ie3. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.8.1.1.3 |
||||
|
aixNetworkInterface
The interface name for the Network adapter. An example
is LO. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.8.1.1.4 |
||||
|
aixNetworkStatus
Indicates the current status of the adapter.
Possible values are available, indicating that the adapter is configured in the system and ready to be used, and defined, indicating that the adapter is defined on the s… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.8.1.1.5 |
||||
|
aixNetworkLocation
The location code for the Network adapter. An example
is 10-60. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.8.1.1.6 |
||||
|
aixNetworkDescr
Defines a short text description of the adapter. An example is
IEEE 802.3 Ethernet Network Interface |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.8.1.1.7 |
aixAdapterTable
table.1.3.6.1.4.1.2.6.191.9.9.1
·
1 row entry
·
7 columns
A table of adapters.
An entry of the adapter
Indexes
aixAdapterIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
aixAdapterName
Identifies the logical name of the adapter.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.9.1.1.1 |
||||
|
aixAdapterIndex
The index for the adapter table.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2.6.191.9.9.1.1.2 |
||||
|
aixAdapterType
The type of the adapter. An example
is keyboard. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.9.1.1.3 |
||||
|
aixAdapterInterface
The interface name for the adapter. An example
is pci. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.9.1.1.4 |
||||
|
aixAdapterStatus
Indicates the current status of the .
Possible values are available, indicating that the is configured in the system and ready to be used, and defined, indicating that the is defined on the system but not configu… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2.6.191.9.9.1.1.5 |
||||
|
aixAdapterLocation
The location code for the adapter. An example
is 01-K1-00. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.9.1.1.6 |
||||
|
aixAdapterDescr
Defines a short text description of the . An example is
Keyboard Adapter |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2.6.191.9.9.1.1.7 |