hwVOPGfastSNRMarginConfProfMinSnrmRmcUs

HUAWEI-VOP-MIB · .1.3.6.1.4.1.2011.6.144.1.1.14.1.43

Object

column r/w 0.1 dB Unsigned32
Defines the upstream minimum noise margin the FTU-O receiver tolerates for the RMC. 
If the downstream RMC noise margin falls below this level, the FTU-O initiates the RPA procedure.
The minimum noise margin ranges from 0 to 310 units of 0.1 dB (Physical values are 0 to 31 dB).
A value of 0 means that there is no minimum.
Unit: 0.1 dB.

Context

MIB
HUAWEI-VOP-MIB
OID
.1.3.6.1.4.1.2011.6.144.1.1.14.1.43
Type
column
Access
readwrite
Status
current
Units
0.1 dB
Parent
hwVOPSNRMarginConfProfEntry
Table
hwVOPSNRMarginConfProfTable
Siblings
44

Syntax

0.1 dB Unsigned32

Values & Constraints

Object Constraints
range: 0-310

Related Objects

Sibling Objects