vdsl2SCStatusBandSigAtten

HUAWEI-VDSL2-LINE-MIB · .1.3.6.1.4.1.2011.6.115.1.2.4.1.3

Object

column 0.1 dB Unsigned32
When referring to a band the downstream direction, it is the
measured difference in the total power transmitted by the
xTU-C and the total power received by the xTU-R over all sub
carriers during Showtime after the diagnostics mode.
When referring to the upstream direction, it is the measured
difference in the total power transmitted by the
xTU-R and the total power received by the xTU-C over all sub
carriers during Showtime after the diagnostics mode.
It ranges from 0 to 1270 units of 0.1 dB (Physical values
are 0 to 127 dB).
A special value of 0x7FFFFFFF (2147483647) indicates the line
attenuation is out of range to be represented.
A special value of 0x7FFFFFFE (2147483646) indicates the line
attenuation measurement is unavailable.
This object reflects the value of the parameter following the
most recent DELT performed on the associated line.  Once
the DELT process is over, the parameter no longer changes
until the row is deleted or a new DELT process is initiated.
Unit: 0.1 dB

Context

MIB
HUAWEI-VDSL2-LINE-MIB
OID
.1.3.6.1.4.1.2011.6.115.1.2.4.1.3
Type
column
Access
readonly
Status
current
Units
0.1 dB
Parent
vdsl2SCStatusBandEntry
Table
vdsl2SCStatusBandTable
Siblings
4

Syntax

0.1 dB Unsigned32

Values & Constraints

Object Constraints
range: 0-1270 range: 2147483646-2147483647

Related Objects