vdsl2LinePerfCorrectedThreshXtuc
HUAWEI-VDSL2-LINE-MIB ·
.1.3.6.1.4.1.2011.6.115.1.0.13
Object
notification
This notification indicates that the corrected blocks (FEC events) threshold has been reached/exceeded for the referred xTU-C.
Context
- MIB
- HUAWEI-VDSL2-LINE-MIB
- OID
.1.3.6.1.4.1.2011.6.115.1.0.13- Type
- notification
- Status
- current
- Parent
- vdsl2Notifications
- Siblings
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdsl2LinePerfFECSThreshXtuc This notification indicates that the FEC seconds threshold
has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.1 |
| vdsl2LinePerfUASThreshXtur This notification indicates that the unavailable seconds
threshold has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.10 |
| vdsl2LinePerfCodingViolationsThreshXtuc This notification indicates that the coding violations
threshold has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.11 |
| vdsl2LinePerfCodingViolationsThreshXtur This notification indicates that the coding violations
threshold has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.12 |
| vdsl2LinePerfCorrectedThreshXtur This notification indicates that the corrected blocks
(FEC events) threshold has been reached/exceeded for the
referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.14 |
| vdsl2LinePerfFailedFullInitThresh This notification indicates that the failed full
initializations threshold has been reached/exceeded for the
referred VDSL/VDSL2 or VDSL2 line. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.15 |
| vdsl2LinePerfFailedShortInitThresh This notification indicates that the failed short
initializations threshold has been reached/exceeded for the
referred VDSL or VDSL2 line. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.16 |
| vdsl2LineStatusChangeXtuc This notification indicates that a status change is
detected for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.17 |
| vdsl2LineStatusChangeXtur This notification indicates that a status change is
detected for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.18 |
| vdsl2LinePerfFullInitThresh This notification indicates that the full
initializations threshold has been reached/exceeded for the
referred VDSL/VDSL2 or VDSL2 line. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.19 |
| vdsl2LinePerfFECSThreshXtur This notification indicates that the FEC seconds threshold
has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.2 |
| vdsl2LinePerfESThreshXtuc This notification indicates that the errored seconds threshold
has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.3 |
| vdsl2LinePerfESThreshXtur This notification indicates that the errored seconds threshold
has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.4 |
| vdsl2LinePerfSESThreshXtuc This notification indicates that the severely-errored seconds
threshold has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.5 |
| vdsl2LinePerfSESThreshXtur This notification indicates that the severely-errored seconds
threshold has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.6 |
| vdsl2LinePerfLOSSThreshXtuc This notification indicates that the LOS seconds
threshold has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.7 |
| vdsl2LinePerfLOSSThreshXtur This notification indicates that the LOS seconds
threshold has been reached/exceeded for the referred xTU-R. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.8 |
| vdsl2LinePerfUASThreshXtuc This notification indicates that the unavailable seconds
threshold has been reached/exceeded for the referred xTU-C. | notification | - | .1.3.6.1.4.1.2011.6.115.1.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdsl2PMChCurr15MCorrectedBlocks Count of FEC (FFEC for xTU-R) anomalies (corrected code words)
occurring in the channel during the interval. This parameter
is inhibited during UAS or SES. If the FEC is applied… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.115.1.4.2.1.1.6 |
| vdsl2ChAlarmConfProfileXtucThresh15MinCorrected A threshold for the vdsl2PMChCurr15MCorrectedBlocks
counter, when vdsl2PMChCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.115.1.5.3.3.1.3 |