hwVdsl2LineAlarmConfProfileReceivedESAbnormalAlarmSwitch
HUAWEI-VDSL2-LINE-MIB ·
.1.3.6.1.4.1.2011.6.115.1.5.3.2.1.24
Object
column
r/w
Enumeration
This object enable/disable the alarm switch that The port
receives abnormal error sample messages.
Options:
1. enable(1) - The alarm switch that the port receives
abnormal error sample messages is enabled
2. disable(2) - The alarm switch that the port receives
abnormal error sample messages is disabled
Context
- MIB
- HUAWEI-VDSL2-LINE-MIB
- OID
.1.3.6.1.4.1.2011.6.115.1.5.3.2.1.24- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vdsl2LineAlarmConfProfileEntry
- Table
- vdsl2LineAlarmConfProfileTable
- Siblings
- 26
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | enable |
2 | disable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdsl2LineAlarmConfProfileName This object identifies a row in this table. | column | OctetString | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.1 |
| vdsl2LineAlarmConfProfileXturThresh15MinLoss A threshold for the vdsl2PMLCurr15MLoss counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.10 |
| vdsl2LineAlarmConfProfileXturThresh15MinUas A threshold for the vdsl2PMLCurr15MUas counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.11 |
| vdsl2LineAlarmConfProfileThresh15MinFailedFullInt A threshold for the vdsl2PMLCurrInit15MfailedFullInits
counter.
The value 0 means that no threshold is specified for the
associated counter. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.12 |
| vdsl2LineAlarmConfProfileThresh15MinFailedShrtInt A threshold for the vdsl2PMLCurrInit15MFailedShortInits
counter.
The value 0 means that no threshold is specified for the
associated counter. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.13 |
| vdsl2LineAlarmConfProfileRowStatus This object is used to create a new row or to modify or
delete an existing row in this table.
A profile is activated by setting this object to 'active'.
When 'activ… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.14 |
| vdsl2LineAlarmConfProfileThresh15MinFullInt A threshold for the vdsl2PMLCurrInit15MFullInits
counter.
The value 0 means that no threshold is specified for the
associated counter. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.15 |
| vdsl2LineAlarmConfProfileXtucThresh15MinLeftrs A threshold for the vdsl2PMLCurr15MLeftrs counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.16 |
| vdsl2LineAlarmConfProfileXturThresh15MinLeftrs A threshold for the vdsl2PMLCurr15MLeftrs counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.17 |
| hwVdsl2LineAlarmConfProfileDyingGaspAlarmSwitch This object enable/disable the report of LOSS-OF-POWER
alarm in a VDSL line.
Options:
1. enable(1) - The report of LOSS-OF-POWER alarm in a VDSL line is enabled
2. disable(2) - T… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.18 |
| hwVdsl2LineAlarmConfProfileActiveFailAlarmSwitch This object enable/disable the active fail alarm switch.
Options:
1. enable(1) - The active fail alarm switch is enabled
2. disable(2) - The active fail alarm switch is disabled | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.19 |
| vdsl2LineAlarmConfProfileXtucThresh15MinFecs A threshold for the vdsl2PMLCurr15MFecs counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.2 |
| hwVdsl2LineAlarmConfProfileRateChangeAlarmSwitch This object enable/disable the active rate change alarm switch.
Options:
1. enable(1) - The active rate change alarm switch is enabled
2. disable(2) - The active rate change ala… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.20 |
| hwVdsl2LineAlarmConfProfileLegacyCpeAlarmSwitch This object enable/disable the legacy cpe alarm switch.
Options:
1. enable(1) - The legacy cpe alarm switch is enabled
2. disable(2) - The legacy cpe alarm switch is disabled | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.21 |
| hwVdsl2LineAlarmConfProfileVictAbnormalVariationAlarmSwitch This object enable/disable alarm switch that the port
receives abnormal crosstalk.
Options:
1. enable(1) - The alarm switch that the port receives
abnormal cros… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.22 |
| hwVdsl2LineAlarmConfProfileDistAbnormalVariationAlarmSwitch This object enable/disable the alarm switch that the port
causes abnormal crosstalk.
Options:
1. enable(1) - The alarm switch that the port causes
abnormal cross… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.23 |
| hwVdsl2LineAlarmConfProfileNonVectoringCPEActivatedAlarmSwitch This object enable/disable the alarm switch that the port is
activated in none-vectoring mode.
Options:
1. enable(1) - The alarm switch that the port is activated
… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.25 |
| hwVdsl2LineAlarmConfProfileFreqRetrainReachThresholdAlarmSwitch This object enable/disable the alarm switch that the port
frequently retrain times in 15 minutes reach the threshold.
Options:
1. enable(1) - The alarm switch that the port freq… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.26 |
| hwvdsl2LineAlarmConfProfilePSConfigAbnormalAlarmSwitch This object enable/disable the pilot sequence configuration abnormal alarm switch.
Options:
1. enable(1) - The pilot sequence configuration abnormal alarm switch is enabled
2. d… | column | Enumeration | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.27 |
| vdsl2LineAlarmConfProfileXtucThresh15MinEs A threshold for the vdsl2PMLCurr15MEs counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.3 |
| vdsl2LineAlarmConfProfileXtucThresh15MinSes A threshold for the vdsl2PMLCurr15MSes counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.4 |
| vdsl2LineAlarmConfProfileXtucThresh15MinLoss A threshold for the vdsl2PMLCurr15MLoss counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.5 |
| vdsl2LineAlarmConfProfileXtucThresh15MinUas A threshold for the vdsl2PMLCurr15MUas counter,
when vdsl2PMLCurrUnit is XTUC {1}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.6 |
| vdsl2LineAlarmConfProfileXturThresh15MinFecs A threshold for the vdsl2PMLCurr15MFecs counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.7 |
| vdsl2LineAlarmConfProfileXturThresh15MinEs A threshold for the vdsl2PMLCurr15MEs counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.8 |
| vdsl2LineAlarmConfProfileXturThresh15MinSes A threshold for the vdsl2PMLCurr15MSes counter,
when vdsl2PMLCurrUnit is XTUR {2}.
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.115.1.5.3.2.1.9 |