hwClrAlarmExpSignal

HUAWEI-SNMP-NOTIFICATION-MIB · .1.3.6.1.4.1.2011.6.30.12.2

Object

scalar r/w Enumeration
It is used to clear the alarm output signal. After the alarm output signal is cleared, 
the recovery notification is sent to the external alarm interface and the corresponding 
active alarm is cleared. For the current external alarm interface, only the one-LED and 
three-LED output mode is supported. In the one-LED output mode, the alarm output signal 
cannot be cleared by level and can be cleared only by all(1); In the three-LED output mode,
the alarm output signal can be cleared by all the following parameters. 
Options:                                                               
1. other(-1)   -indicates the default status in the system.
2. all(1)      -indicates that all the alarm output signals are cleared.
3. critical(2) -indicates that the critical alarm output signal is cleared. 
4. major(3)    -indicates that the major alarm output signal is cleared. 
5. minor(4)    -indicates that the minor alarm output signal is cleared.

Context

MIB
HUAWEI-SNMP-NOTIFICATION-MIB
OID
.1.3.6.1.4.1.2011.6.30.12.2
Type
scalar
Access
readwrite
Status
current
Parent
hwAlarmExpSignal
Siblings
1

Syntax

Enumeration

Values & Constraints

Enumerated Values
-1other
1all
2critical
3major
4minor

Related Objects