hwAlarmSynAdminStatus

HUAWEI-SNMP-NOTIFICATION-MIB · .1.3.6.1.4.1.2011.6.30.1.5

Object

scalar r/w Enumeration
When the alarm whose synchronization is initiated by the NMS, 
one of the following methods can be used:  
Options:
1. other(1)    -other.                                 
2. stop(2)     -stop. 
3. interval(3) -indicates that synchronize the alarm by serial number (that is, synchronize
                all the alarms in the system). During the synchronization, 
                hwAlarmSynBeginSn, hwAlarmSynEndSn and hwSynTrapAdminStatus need to be issued.
                The corresponding value is interval(3).
4. all(4)      -indicates that synchronize all the active alarms (the active alarms refer 
                to the alarm whose fault alarms are already sent but the 
                corresponding recovery alarms are not sent). 
                hwSynTrapAdminStatus is issued directly and the corresponding value is all (4).

Context

MIB
HUAWEI-SNMP-NOTIFICATION-MIB
OID
.1.3.6.1.4.1.2011.6.30.1.5
Type
scalar
Access
readwrite
Status
current
Parent
hwAlarmSynObjects
Siblings
6

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2stop
3interval
4all

Related Objects