hwBatteryLogTestFinish
HUAWEI-POWER-MIB ·
.1.3.6.1.4.1.2011.6.2.1.6.5.1.7
Object
column
Enumeration
Battery Test result. Options: 1. testing(1) - indicates that it is during testing 2. completed(2) - indicates that the test is completed normally 3. alarmTerminated(3) - indicates that the test is stopped by alarms 4. hostTerminated(4) - indicates that the test is stopped by the host 5. overtimeTerminated(5) - indicates that the test is stopped because of over 100 hours 6. notTest(6) - indicates that the test is not started 7. supplyRecoverAutotestTerminated(7) - indicates that the test is stopped because of supply recover
Context
- MIB
- HUAWEI-POWER-MIB
- OID
.1.3.6.1.4.1.2011.6.2.1.6.5.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwBatteryLogTestEntry
- Table
- hwBatteryLogTestTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | testing |
2 | completed |
3 | alarmTerminated |
4 | hostTerminated |
5 | overtimeTerminated |
6 | notTest |
7 | supplyRecoverAutotestTerminated |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwBatteryLogTestIndex Battery discharge test result index | column | Integer32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.1 |
| hwBatteryLogTestBatteryCurrent Battery discharge test average Current.
Unit: mA | column | mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.10 |
| hwBatteryLogTestStartTime Battery discharge test start time | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2011.6.2.1.6.5.1.2 |
| hwBatteryLogTestDischargeDuration Duration of discharge.
Unit: minute | column | minute SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.3 |
| hwBatteryLogTestTerminateVoltage End voltage of battery discharge test .
Unit: mV | column | mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.4 |
| hwBatteryLogTestBatteryStatus Battery status.
Options:
1. expectant(1) - indicates the batter test state is expectant
2. unexpected(2) - indicates the batter test state is unexpected
3. unknown(3) - indicate… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.6.5.1.5 |
| hwBatteryLogTestTotalDischargeAH Discharge cumulate AH.
Unit: mAH | column | mAH SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.6 |
| hwBatteryLogTestEfficiency The information of battery test efficiency. | column | percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.8 |
| hwBatteryLogTestBatteryTemperature Battery discharge test end Temperature.
Unit: 0.01 Degree
Invaild: 0X7FFFFFFF | column | 0.01 Degree SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.2.1.6.5.1.9 |