hwLineTestParaOprType
HUAWEI-NTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.2.1.1.35.1.1
Object
column
r/w
Enumeration
The operation type of Test para config. Options: 1. configure(1) -configure the value of physical layer test para 2. restore(2) -restore the value of physical layer test para 3. invalid(-1) -invalid value
Context
- MIB
- HUAWEI-NTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.2.1.1.35.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwLineTestParaEntry
- Table
- hwLineTestParaTable
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
Enumerated Values
-1 | invalid |
1 | configure |
2 | restore |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwLineTestParaFrameIndex Indicates the frameID of configuring test para.
Range: 0-255|-1 | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.2 |
| hwLineTestParaSlotIndex Indicates the slotID of configuring test para.
Range: 0-255|-1 | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.3 |
| hwLineTestParaPv Indicates the peak line test voltage of permitted sending.
Range: 0-100000|-1
Default: 50000
Unit: mV | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.4 |
| hwLineTestParaAcF Indicates the AC signal frequency when testing the capacitance and catheter.
Range: 10-1000|-1
Default: 25
Unit: Hz | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.5 |
| hwLineTestParaPitF Indicates the frequency of line test voice.
Range: 300-3400|-1
Default: 800
Unit: Hz | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.6 |
| hwLineTestParaMaxfeScv Indicates the max voltage of Signature test.
Range: 0-50000|-1
Default: 50000
Unit: mV
Step: 1000 | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.7 |
| hwLineTestParaMinfeScv Indicates the min voltage of Signature test.
Range: 0-50000|-1
Default: 3000
Unit: mV
Step: 1000 | column | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.35.1.8 |