hwIsdnUserInTestOprEntry
HUAWEI-NTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.2.1.1.2.1
Object
row
Describes the Operation table for the ISDN subscriber circuit test: It realizes the function of the circuit test for ISDN subscribers in the system. In the circuit test, the status (activated, deactivated) of the LT U port, LT power supply voltage, LT power supply overflow auto protection, manual switch-off line feeding voltage, and manual switch-on line feeding voltage are measured. The test result shows whether the ISDN subscriber circuit works in the normal state. The index of this entry is ifIndex.
Context
- MIB
- HUAWEI-NTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.2.1.1.2.1- Type
- row
- Status
- current
- Parent
- hwIsdnUserInTestOprTable
- Table
- hwIsdnUserInTestOprTable
- Children
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwIsdnUserInTestOprType Describes the Operation type.
Options:
1. stop(1) -stop the test
2. start(2) -start the test | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.1 |
| hwIsdnUserInTestActiveResult Describes the Activation result .
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. outOfTime(3) -indi… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.10 |
| hwIsdnUserInTestDeactiveResult Describes the Deactivation result.
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. outoftime(3) -ind… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.11 |
| hwIsdnUserInTestLtSupplyPowerCap LT power supply voltage
Unit: millivolt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.12 |
| hwIsdnUserInTestLtSupplyPowerCapResult Describes the Test result-LT power supply voltage.
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. outOfTime(3) … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.13 |
| hwIsdnUserInTestLtCurrentProctectResult Describes the LT over current auto-protection capability .
Options:
1. outOfTime(1) -indicates timed-out
2. noProtect(2) -indicates not protected
… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.14 |
| hwIsdnUserInTestCutLineVolVal Describes the Manual switch-off line feeding voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.15 |
| hwIsdnUserInTestCutLineVolResult Describes the Test result-Manual switch-off line feeding voltage.
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. out… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.16 |
| hwIsdnUserInTestSwitchOnVolVal Describes the Switch on voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.17 |
| hwIsdnUserInTestSwitchOnVolResult Describes the Test result-switch on voltage.
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. outOfTime(3) -in… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.18 |
| hwIsdnUserInTestActive Describes the ISDN subscriber circuit test-Active.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.2 |
| hwIsdnUserInTestDeactive Describes the ISDN circuit test-Deactive.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.3 |
| hwIsdnUserInTestLtSupplyPowerVol Describes the ISDN circuit test-LT supply power.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.4 |
| hwIsdnUserInTestLtCurrentProctect Describes the ISDN circuit test-LT power supply overflow auto protection .
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.5 |
| hwIsdnUserInTestCutLineVol Describes the ISDN circuit test-Manual switch-off line feeding voltage.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.6 |
| hwIsdnUserInTestSwitchOnVol Describes the ISDN circuit test-Manual switch-on line feeding voltage .
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.7 |
| hwIsdnUserInTestBusyProcFlag Describes the Busy control flag .
Options:
1. busynotest(1) -no test when busy
2. busytest(2) -remedy test when busy
3. busystrentest(3) -forced test on busy | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.8 |
| hwIsdnUserInTestStatus Describes the Test status .
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. portbusy(3) -indicates busy port … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.2.1.9 |