hwOpticsDdmInfoExSubType
HUAWEI-LINE-COMMON-MIB ·
.1.3.6.1.4.1.2011.6.158.1.1.1.1.1.31
Object
column
Enumeration
Options: 1. classbplus(1) - CLASS B+ 2. classcplus(2) - CLASS C+ 3. classb(3) - CLASS B 4. classcplusplus(4) - CLASS C++ 5. classd(5) - CLASS D 6. n2a(33) - N2a 7. n2b(34) - N2b 8. n1(35) - N1 9. e1(36) - E1 10. e2a(37) - N2a 11.e2b(38) - N2b 12.n1n2ae1e2a(39) - N1/N2a/E1/E2a 13.d1(40) - D1 14.d2(41) - D2 15.n2(42) - N2 16.e2(43) - E2 17.px20(65) - PX20 18.px20plus(66) - PX20+ 19.px20plusplus(67) - PX20++ 20.pr30(97) - PR30 21.pr20(98) - PR20 22.prx30(99) - PRX30 23.prx20(100) - PRX20 24.prx40(101) - PRX40 25.pr40(102) - PR40 26.prx30e(103) - PRX30-E 27.prx40e(104) - PRX40-E 28.pr30plus(105) - PR30+ 29.classbPlusAndPx20Plus(129) - GPON CLASS B+/EPON PX20+ 30.classbAndPx20(130) - GPON CLASS B/EPON PX20 31.unknown(145) - Unknown 32.invalid(-1) - Indicates that the query fails or no information is detected
Context
- MIB
- HUAWEI-LINE-COMMON-MIB
- OID
.1.3.6.1.4.1.2011.6.158.1.1.1.1.1.31- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwOpticsDdmInfoExEntry
- Table
- hwOpticsDdmInfoExTable
- Siblings
- 34
Syntax
Enumeration
Values & Constraints
Enumerated Values
-1 | invalid |
1 | classbplus |
2 | classcplus |
3 | classb |
4 | classcplusplus |
5 | classd |
33 | n2a |
34 | n2b |
35 | n1 |
36 | e1 |
37 | e2a |
38 | e2b |
39 | n1n2ae1e2a |
40 | d1 |
41 | d2 |
42 | n2 |
43 | e2 |
65 | px20 |
66 | px20plus |
67 | px20plusplus |
97 | pr30 |
98 | pr20 |
99 | prx30 |
100 | prx20 |
101 | prx40 |
102 | pr40 |
103 | prx30e |
104 | prx40e |
105 | pr30plus |
129 | classbPlusAndPx20Plus |
130 | classbAndPx20 |
145 | unknown |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwOpticsDdmInfoExTemperature Temperature of the optical transceiver.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.1 |
| hwOpticsDdmInfoExSupplyVoltageLowWarningThreshold Lower warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.10 |
| hwOpticsDdmInfoExTxBiasCurrent Current of the optical transceiver.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.11 |
| hwOpticsDdmInfoExTxBiasCurrentHighAlarmThreshold Upper alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.12 |
| hwOpticsDdmInfoExTxBiasCurrentLowAlarmThreshold Lower alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.13 |
| hwOpticsDdmInfoExTxBiasCurrentHighWarningThreshold Upper warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.14 |
| hwOpticsDdmInfoExTxBiasCurrentLowWarningThreshold Lower warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.15 |
| hwOpticsDdmInfoExTxPower Tx optical power of the optical transceiver.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.16 |
| hwOpticsDdmInfoExTxPowerHighAlarmThreshold Upper alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.17 |
| hwOpticsDdmInfoExTxPowerLowAlarmThreshold Lower alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.18 |
| hwOpticsDdmInfoExTxPowerHighWarningThreshold Upper warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.19 |
| hwOpticsDdmInfoExTemperatureHighAlarmThreshold Upper alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.2 |
| hwOpticsDdmInfoExTxPowerLowWarningThreshold Lower warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.20 |
| hwOpticsDdmInfoExRxPower Rx optical power of the optical transceiver.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.21 |
| hwOpticsDdmInfoExRxPowerHighAlarmThreshold Upper alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.22 |
| hwOpticsDdmInfoExRxPowerLowAlarmThreshold Lower alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.23 |
| hwOpticsDdmInfoExRxPowerHighWarningThreshold Upper warning threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.24 |
| hwOpticsDdmInfoExRxPowerLowWarningThreshold Lower warning threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.25 |
| hwOpticsDdmInfo10GTxBiasCurrent Current of the 10g optical transceiver.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.26 |
| hwOpticsDdmInfo10GTxPower Tx optical power of the 10g optical transceiver.
Unit: 0.01dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.01dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.27 |
| hwOpticsDdmInfoExCatvRxPowerHighAlarmThreshold Upper AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.28 |
| hwOpticsDdmInfoExCatvRxPowerLowAlarmThreshold Lower AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.29 |
| hwOpticsDdmInfoExTemperatureLowAlarmThreshold Lower alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.3 |
| hwOpticsDdmInfoExModuleType Options:
1. gpon(1) - GPON
2. epon(2) - EPON
3. epon10g(3) - 10G EPON
4. gpon10g(4) - 10G GPON
5. wdmpon(5) - WDM PON
6. hybridpon(6… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.30 |
| hwOpticsDdmInfoExPrecision This object indicates the precision of optical power.
Unit: 0.1dBm
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.1dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.32 |
| hwOpticsDdmInfoExEncapsulationType Options:
1. sff2x5(1) - SFF 2x5
2. sff2x10(2) - SFF 2x10
3. sfp(3) - SFP
4. xfp(4) - XFP
5. lxfp(5) - … | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.33 |
| hwOpticsDdmInfoExVendorPN This object indicates the part number. | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.34 |
| hwOpticsDdmInfoExUsedType This object indicates the application scenario of the optical transceiver.
Options:
1. olt(1) - OLT
2. onu(3) - ONU
3. catvtriplex(4) - CAT… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.35 |
| hwOpticsDdmInfoExTemperatureHighWarningThreshold Upper warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.4 |
| hwOpticsDdmInfoExTemperatureLowWarningThreshold Lower warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.5 |
| hwOpticsDdmInfoExSupplyVoltage Voltage of the optical transceiver.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.6 |
| hwOpticsDdmInfoExSupplyVoltageHighAlarmThreshold Upper alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.7 |
| hwOpticsDdmInfoExSupplyVoltageLowAlarmThreshold Lower alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.8 |
| hwOpticsDdmInfoExSupplyVoltageHighWarningThreshold Upper warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.9 |