hwOpticsDdmInfoExRxPowerHighWarningThreshold
HUAWEI-LINE-COMMON-MIB ·
.1.3.6.1.4.1.2011.6.158.1.1.1.1.1.24
Object
Upper warning threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
Context
- MIB
- HUAWEI-LINE-COMMON-MIB
- OID
.1.3.6.1.4.1.2011.6.158.1.1.1.1.1.24- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.000001dBm
- Parent
- hwOpticsDdmInfoExEntry
- Table
- hwOpticsDdmInfoExTable
- Siblings
- 34
Syntax
0.000001dBm SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwOpticsDdmInfoExTemperature Temperature of the optical transceiver.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.1 |
| hwOpticsDdmInfoExSupplyVoltageLowWarningThreshold Lower warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.10 |
| hwOpticsDdmInfoExTxBiasCurrent Current of the optical transceiver.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.11 |
| hwOpticsDdmInfoExTxBiasCurrentHighAlarmThreshold Upper alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.12 |
| hwOpticsDdmInfoExTxBiasCurrentLowAlarmThreshold Lower alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.13 |
| hwOpticsDdmInfoExTxBiasCurrentHighWarningThreshold Upper warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.14 |
| hwOpticsDdmInfoExTxBiasCurrentLowWarningThreshold Lower warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.15 |
| hwOpticsDdmInfoExTxPower Tx optical power of the optical transceiver.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.16 |
| hwOpticsDdmInfoExTxPowerHighAlarmThreshold Upper alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.17 |
| hwOpticsDdmInfoExTxPowerLowAlarmThreshold Lower alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.18 |
| hwOpticsDdmInfoExTxPowerHighWarningThreshold Upper warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.19 |
| hwOpticsDdmInfoExTemperatureHighAlarmThreshold Upper alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.2 |
| hwOpticsDdmInfoExTxPowerLowWarningThreshold Lower warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.20 |
| hwOpticsDdmInfoExRxPower Rx optical power of the optical transceiver.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.21 |
| hwOpticsDdmInfoExRxPowerHighAlarmThreshold Upper alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.22 |
| hwOpticsDdmInfoExRxPowerLowAlarmThreshold Lower alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.23 |
| hwOpticsDdmInfoExRxPowerLowWarningThreshold Lower warning threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.25 |
| hwOpticsDdmInfo10GTxBiasCurrent Current of the 10g optical transceiver.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.26 |
| hwOpticsDdmInfo10GTxPower Tx optical power of the 10g optical transceiver.
Unit: 0.01dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.01dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.27 |
| hwOpticsDdmInfoExCatvRxPowerHighAlarmThreshold Upper AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.28 |
| hwOpticsDdmInfoExCatvRxPowerLowAlarmThreshold Lower AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.29 |
| hwOpticsDdmInfoExTemperatureLowAlarmThreshold Lower alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.3 |
| hwOpticsDdmInfoExModuleType Options:
1. gpon(1) - GPON
2. epon(2) - EPON
3. epon10g(3) - 10G EPON
4. gpon10g(4) - 10G GPON
5. wdmpon(5) - WDM PON
6. hybridpon(6… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.30 |
| hwOpticsDdmInfoExSubType Options:
1. classbplus(1) - CLASS B+
2. classcplus(2) - CLASS C+
3. classb(3) - CLASS B
4. classcplusplus(4) - CLA… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.31 |
| hwOpticsDdmInfoExPrecision This object indicates the precision of optical power.
Unit: 0.1dBm
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.1dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.32 |
| hwOpticsDdmInfoExEncapsulationType Options:
1. sff2x5(1) - SFF 2x5
2. sff2x10(2) - SFF 2x10
3. sfp(3) - SFP
4. xfp(4) - XFP
5. lxfp(5) - … | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.33 |
| hwOpticsDdmInfoExVendorPN This object indicates the part number. | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.34 |
| hwOpticsDdmInfoExUsedType This object indicates the application scenario of the optical transceiver.
Options:
1. olt(1) - OLT
2. onu(3) - ONU
3. catvtriplex(4) - CAT… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.35 |
| hwOpticsDdmInfoExTemperatureHighWarningThreshold Upper warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.4 |
| hwOpticsDdmInfoExTemperatureLowWarningThreshold Lower warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.5 |
| hwOpticsDdmInfoExSupplyVoltage Voltage of the optical transceiver.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.6 |
| hwOpticsDdmInfoExSupplyVoltageHighAlarmThreshold Upper alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.7 |
| hwOpticsDdmInfoExSupplyVoltageLowAlarmThreshold Lower alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.8 |
| hwOpticsDdmInfoExSupplyVoltageHighWarningThreshold Upper warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.1.1.9 |