hwFanSpeed
HUAWEI-ENVIRONMENT-MIB ·
.1.3.6.1.4.1.2011.6.1.1.5.1.9
Object
When hwFanSpeedMode is the continue mode, 0 indicates the present wind speed +1, while 1 indicates the present wind speed -1. When hwFanSpeedMode is discontinuous, 0 indicates fixed high speed, while 1 indicates fixed low speed. When hwFanSpeedMode is percent, the value delivered by the main control is the percent value, ranging from 35 to 100, used to initialize the rotation of fan for various device main controls. invalid(-1) indicates that the fan tray does not work normally. For example, the fan tray is disconnected from the control board, or some of the fans in the fan tray are blocked.
Context
- MIB
- HUAWEI-ENVIRONMENT-MIB
- OID
.1.3.6.1.4.1.2011.6.1.1.5.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwFanEntry
- Table
- hwFanTable
- Siblings
- 9
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwFanName Fan name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2011.6.1.1.5.1.1 |
| hwFanTypeDescription Fan Type Description.
Invalid: null string. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2011.6.1.1.5.1.10 |
| hwFanControlMode The fan control modes of the fan frame.
Options:
1.manual(1) -indicates that the fan is always on, and the fan speed can be manually adjusted
2.emuAuto(2) -indicates… | column | Enumeration | .1.3.6.1.4.1.2011.6.1.1.5.1.2 |
| hwFanControlState For ESC fan, all should be checked to turn on the fan,
while all should not be checked to turn off the fan.
Options:
1.fan1(0) -indicates that the first fan needs to be opened
2.… | column | Bits | .1.3.6.1.4.1.2011.6.1.1.5.1.3 |
| hwESCFanTempAutoOn The fan temperature set, in unit of centigrade.
The MIB object only functions for the fan monitoring board of ESC and
is not applicable to the type of fan monitoring board.
Only… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.1.1.5.1.4 |
| hwESCFanTempAutoOff The fan temperature set, in unit of centigrade.
The MIB object only functions for the fan monitoring board of ESC and
is not applicable to the type of fan monitoring board.
Onl… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.1.1.5.1.5 |
| hwFanRowStatus RowStatus standard operation. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.1.1.5.1.6 |
| hwCurrentTemp The present temperature value
Unit: 0.01 degree
invalid: 0x7fffffff | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.1.1.5.1.7 |
| hwFanSpeedMode The adjusting rotation mode of the fan.
Options:
1.continue(1) -continuous control
2.discontinue(2) -discrete control
3.percent(3) -duty ratio control
4.invalid(-1) -ind… | column | Enumeration | .1.3.6.1.4.1.2011.6.1.1.5.1.8 |