hwESCFanTempAutoOff

HUAWEI-ENVIRONMENT-MIB · .1.3.6.1.4.1.2011.6.1.1.5.1.5

Object

column r/w SNMPv2-SMIInteger32
The fan temperature set, in unit of centigrade. 
The MIB object only functions for the fan monitoring board of ESC and 
is not applicable to the type of fan monitoring board. 
Only when the fan control mode of the fan frame is hwFanControl =auto (3),
the temperature control mode will take effect. 
When detecting the environment temperature is lower than the set value, 
the fan will be turned off (decrease its rotation).

Context

MIB
HUAWEI-ENVIRONMENT-MIB
OID
.1.3.6.1.4.1.2011.6.1.1.5.1.5
Type
column
Access
readwrite
Status
current
Parent
hwFanEntry
Table
hwFanTable
Siblings
9

Syntax

SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects