hwadslLineAlarmConfProfileCfgEntry
HUAWEI-ADSL-EXT-MIB ·
.1.3.6.1.4.1.2011.6.31.1.21.1
Object
row
This table contains information on the ADSL line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the modem for a physical line. The entry contains information on the ADSL line configuration. Each entry consists of a list of parameters that represents the configuration of an ADSL modem. When 'dynamic' profiles are implemented, a default profile will always exist. This profile's name will be set to 'DEFVAL' and its parameters will be set to vendor specific values, unless otherwise specified in this document. When 'static' profiles are implemented, profiles are automatically created or destroyed as ADSL physical lines are discovered and removed by the system. The name of the profile will be equivalent to the decimal value of the line's interface index. The index of this entry is adslLineAlarmConfProfileName.
Context
- MIB
- HUAWEI-ADSL-EXT-MIB
- OID
.1.3.6.1.4.1.2011.6.31.1.21.1- Type
- row
- Status
- current
- Parent
- hwadslLineAlarmConfProfileCfgTable
- Table
- hwadslLineAlarmConfProfileCfgTable
- Children
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwadslLineAlarmConfProfileDyingGaspCfg This object enables/disables the report of LOSS-OF-POWER
alarm in an ADSL line. This object is defaulted enable(1).
Options:
1. enable(1) - The report of LOSS-OF-POWER alarm in a… | column | Enumeration | .1.3.6.1.4.1.2011.6.31.1.21.1.1 |
| hwadslLineAlarmConfProfXturThresh15MinLeftrs A threshold for the hwAdslAturPerfCurr15MLeftrs counter,
The value 0 means that no threshold is specified for the
associated counter.
Unit: seconds | column | seconds HC-PerfHist-TC-MIBHCPerfIntervalThreshold | .1.3.6.1.4.1.2011.6.31.1.21.1.2 |
| hwAdslLineAlarmConfProfileActiveFailAlarmSwitch This object enable/disable the active fail alarm switch.
Options:
1. enable(1) - The active fail alarm switch is enabled
2. disable(2) - The active fail alarm switch is disabled | column | Enumeration | .1.3.6.1.4.1.2011.6.31.1.21.1.3 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| ADSL-LINE-MIBadslLineAlarmConfProfileName This object is used by the line alarm configuration
table in order to identify a row of this table.
When `dynamic' profiles are implemented, the profile
name is use… | column | OctetString | .1.3.6.1.2.1.10.94.1.1.15.1.1 |