hpnicfEntityExtOperStatus
HPN-ICF-ENTITY-EXT-MIB ·
.1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.3
Object
column
HpnicfOperState
The operate state for this object.
Context
- MIB
- HPN-ICF-ENTITY-EXT-MIB
- OID
.1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hpnicfEntityExtStateEntry
- Table
- hpnicfEntityExtStateTable
- Siblings
- 33
Syntax
HpnicfOperState
- Source
- HpnicfOperState
- Base type
Enumeration
Values & Constraints
Type Values
1 | notSupported |
2 | disabled |
3 | enabled |
4 | dangerous |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hpnicfEntityExtPhysicalIndex The index of hpnicfEntityExtStateTable.
This index is identical to entPhysicalIndex in ENTITY-MIB | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.1 |
| hpnicfEntityExtMemSize The size of memory for the entity.
If the amount of memory exceeds 4,294,967,295 bytes,
the value remains 4,294,967,295 bytes. | column | bytes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.10 |
| hpnicfEntityExtUpTime The uptime for the entity. The meaning of uptime is
when the entity is up, and the value of the object
will add 1 seconds while the entity is running. | column | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.11 |
| hpnicfEntityExtTemperature The temperature for the entity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.12 |
| hpnicfEntityExtTemperatureThreshold The threshold for the temperature. When the temperature
exceeds the threshold, a notification will be sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.13 |
| hpnicfEntityExtVoltage The voltage for the entity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.14 |
| hpnicfEntityExtVoltageLowThreshold The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be
sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.15 |
| hpnicfEntityExtVoltageHighThreshold The high-threshold for the voltage.
When voltage greater than high-threshold, a notification will be
sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.16 |
| hpnicfEntityExtCriticalTemperatureThreshold The threshold for the critical Temperature. When temperature
exceeds the critical temperature, a notification will be sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.17 |
| hpnicfEntityExtMacAddress MAC Address of the entity. | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.18 |
| hpnicfEntityExtErrorStatus Indicate the error state of this entity object. Now it only
supports Port, general power supply, RPS power supply and
board/Subcard. It may have one of these values.
The following… | column | Enumeration | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.19 |
| hpnicfEntityExtAdminStatus The administrative state for this object. | column | HpnicfAdminState | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.2 |
| hpnicfEntityExtCpuMaxUsage The maximal CPU usage for the entity in the period of time. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.20 |
| hpnicfEntityExtLowerTemperatureThreshold The threshold for the lower Temperature. When temperature runs
under the threshold, a notification will be sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.21 |
| hpnicfEntityExtShutdownTemperatureThreshold The threshold for the shutdown Temperature. When temperature
exceeds the threshold, a notification will be sent and the entity
will be shutdown. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.22 |
| hpnicfEntityExtPhyMemSize The memory size of entity. This is the physical attribute of entity. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.23 |
| hpnicfEntityExtPhyCpuFrequency The CPU frequency of entity. Unit of measure is MHZ. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.24 |
| hpnicfEntityExtFirstUsedDate The first used date of the entity. | column | OctetString | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.25 |
| hpnicfEntityExtCpuAvgUsage The average CPU usage for the entity in a period of time. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.26 |
| hpnicfEntityExtMemAvgUsage The average memory usage for the entity in a period of time. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.27 |
| hpnicfEntityExtMemType The memory type of entity. | column | OctetString | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.28 |
| hpnicfEntityExtCriticalLowerTemperatureThreshold The threshold for the critical Temperature. When temperature
exceeds the critical lower temperature, a notification will be sent. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.29 |
| hpnicfEntityExtShutdownLowerTemperatureThreshold The threshold for the shutdown Temperature. When temperature
exceeds the lower threshold, a notification will be sent and the entity
will be shutdown. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.30 |
| hpnicfEntityExtCpuUsageRecoverThreshold The recover threshold for the CPU usage. When the CPU usage falls down to
the threshold, a notification is sent. The hpnicfEntityExtCpuUsageRecoverThreshold
must be less than or… | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.31 |
| hpnicfEntityExtMemSizeRev Size of memory space for the entity.
This node is used to replace hpnicfEntityExtMemSize. | column | bytes HCNUM-TCCounterBasedGauge64 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.32 |
| hpnicfEntityExtCpuUsageIn1Minute The CPU usage in last one minute for this entity.
Generally, the overall CPU usage on the entity is
calculated, independent of the number of CPUs on
the entity. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.33 |
| hpnicfEntityExtCpuUsageIn5Minutes The CPU usage in last five minutes for this entity.
Generally, the overall CPU usage on the entity is
calculated, independent of the number of CPUs on
the entity. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.34 |
| hpnicfEntityExtStandbyStatus This object is used for monitoring standby status.
Not all entities support this object. | column | HpnicfStandbyStatus | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.4 |
| hpnicfEntityExtAlarmLight The alarm status for this entity. It does not include
the severity of alarms raised on child components. In
this condition, there will be a alarm light on the entity,
the object s… | column | HpnicfAlarmStatus | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.5 |
| hpnicfEntityExtCpuUsage The CPU usage for this entity. Generally, the overall
CPU usage on the entity is calculated, independent of
the number of CPUs on the entity. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.6 |
| hpnicfEntityExtCpuUsageThreshold The threshold for the CPU usage. When the CPU usage exceeds
the threshold, a notification will be sent. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.7 |
| hpnicfEntityExtMemUsage The memory usage for the entity. This object indicates what
percent of memory are used. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.8 |
| hpnicfEntityExtMemUsageThreshold The threshold for the Memory usage, When the memory usage
exceeds the threshold, a notification will be sent. | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.9 |