hpicfPim6IfGraftRetryInterval

HP-ICF-PIM6 · .1.3.6.1.4.1.11.2.14.11.5.1.122.1.1.4.1.12

Object

column r/w seconds Unsigned32
The minimum interval that must transpire between two 
successive Grafts sent by a router.  This object corresponds 
to the 'Graft_Retry_Period' timer value defined in the PIMv6-DM 
specification.  This object is used only by PIMv6-DM.

Context

MIB
HP-ICF-PIM6
OID
.1.3.6.1.4.1.11.2.14.11.5.1.122.1.1.4.1.12
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
hpicfPim6IfEntry
Table
hpicfPim6IfTable
Siblings
26

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 1-10