hpicfDSnoopV6DatabaseFile
HP-ICF-DHCPv6-SNOOP-MIB ·
.1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.3
Object
A location to store the lease database or to retrieve it after a reboot. The location must be given in the form of a Uniform Resource Locator (URL) as defined in RFC 2396. The permissible character sets and the encoding rules defined in RFC 2396 section 2 apply.
Context
- MIB
- HP-ICF-DHCPv6-SNOOP-MIB
- OID
.1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hpicfDSnoopV6GlobalCfg
- Siblings
- 11
Syntax
SNMP-FRAMEWORK-MIBSnmpAdminString
- Source
- SNMP-FRAMEWORK-MIBSnmpAdminString
- Base type
OctetString
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hpicfDSnoopV6Enable This object provides the administrative status of the
DHCPv6 Snooping feature. This status must be enabled for
DHCPv6 snooping to work. | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.1 |
| hpicfDSnoopV6DatabaseSFTPPassword A location to store the Password of the SFTP Server. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.10 |
| hpicfDSnoopV6DatabaseValidateSFTPServer This object sets the validate-sftp-server flag. When enabled,
the user must login to the SFTP server to verify and accept
the public key of the server. When disabled, the public… | scalar | Enumeration | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.11 |
| hpicfDSnoopV6RateLimit This object sets the DHCPV6 packet transfer rate.
This rate limit is applicable only when DHCPV6 snooping is
enabled. The default rate is 100 packets per sec. | scalar | Unsigned32 | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.12 |
| hpicfDSnoopV6VlanEnable This object contains vid map for vlans on which DHCPV6
Snooping is enabled. A bit that is on (equal to 1)
indicates that DHCPV6 snooping is enabled on corresponding
vlan . | scalar | HP-ICF-TCVidList | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.2 |
| hpicfDSnoopV6DatabaseWriteDelay The number of seconds to delay writing the
DHCPv6 lease database file after a database
change. This allows grouping
multiple database changes into a single
write. The default va… | scalar | seconds Unsigned32 | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.4 |
| hpicfDSnoopV6DatabaseWriteTimeout The number of seconds to wait for the database file transfer
to finish. If file transfer is not over within this period,
a file transfer failure message is displayed. To continue … | scalar | seconds Unsigned32 | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.5 |
| hpicfDSnoopV6OutOfResourcesTrapCtrl This object provides the operational status of DSNOOPv6 out of
resource control trap. The default value is enabled. This
notification trap is sent when the number of bindings ex… | scalar | Enumeration | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.6 |
| hpicfDSnoopV6ErrantReplyTrapCtrl This object provides the operational status of DSNOOPv6 errant
repy control trap. The default value is enabled. This
notification trap is sent when a DHCPv6 reply packet is rece… | scalar | Enumeration | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.7 |
| hpicfDSnoopV6DatabaseFTPort A location to store the port value of the FT Server. The
default port value will be 69 for TFTP and 22 for SFTP. | scalar | Unsigned32 | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.8 |
| hpicfDSnoopV6DatabaseSFTPUsername A location to store the Username of the SFTP Server.
The default value of username is root. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.11.2.14.11.5.1.102.1.1.1.9 |